Min. Order: | 1 Set/Sets |
---|---|
Trade Term: | FOB |
Payment Terms: | L/C, T/T |
Supply Ability: | 1set/month |
Place of Origin: | Shaanxi |
Location: | Xi'an, Shaanxi, China (Mainland) |
---|---|
Business Type: | Manufacturer, Distributor/Wholesaler, Service |
Model No.: | Super safety valve-8" |
---|---|
Means of Transport: | Ocean, Air, Land |
Working pressure: | 105Mpa |
Working temperature: | 400F |
H2s: | As per NACE MR0175 |
Material: | Inconel |
Type: | Surface control |
Size: | 8" |
Condition: | Stock/unused |
Operation: | Remote control |
ID: | 3" |
Production Capacity: | 1set/month |
Packing: | plywood |
Delivery Date: | 90days |
Subsurface control downhole safety valve Inconel
SCSSV downhole safety valve controled by remote control
OPERATIONS GUIDELINES
Typically, the nitrogen charge chamber of the valve is charged with nitrogen to 1000 to 1500 psi. This charge is sufficient to cut 7/32 inch monoconductor cable, but it is not adequate to cut coiled tubing. The valve can
be charged with nitrogen sufficient to cut coiled tubing, but this raises the required hold open pressure. The tool is
capable of cutting 1.50 inch OD x 0.125 inch wall thickness coiled tubing by application of balance line pressure. The
hold open pressure varies with well conditions; however, it is roughly 2.5 times the nitrogen charge pressure.
All lines on the valve will hold 10000 psi, but a differential pressure between the control and balance line should not
exceed 3000 psi under normal circumstances (control line being higher). This prevents the application of excessive
stress to the ball. (10000 psi in the balance line with no control line pressure is within operational limits.)
Typically, the valve is run into the BOP where the valve controls the tubing area while the BOP pipe ram seals off the
annulus.
The valve is controlled by three hydraulic lines, one to each of the following:
• Control Chamber
• Balance Chamber (Nitrogen Chamber)
• Chemical Injection Port
Generally, the balance line does not have pressure applied to it, therefore the floating check valve remains on seat.
However, the balance line can be used for additional closing force if required. The nitrogen charge and spring force
will cut 7/32 inch mono conductor cable or coiled tubing and close the ball valve provided the nitrogen chamber was
charged to the appropriate pressure
The control line is pressurized to hold the ball valve open. The pressure required can be determined by using Table A,
but generally two times the nitrogen dome charge pressure plus 500 psi for lower pressures and temperatures is
sufficient. There is little hydrostatic pressure and no requirement for cutting coiled tubing in most normal operations,
therefore a nitrogen charge of 1000 - 1500 psi is usually sufficient.
(The check valve should be coined in with around 2000 psi when it is new so that it can hold lower pressures more
reliably.)
The chemical injection line is rated for 15000 psi and can be used for chemical injection downhole or to control a
subsurface safety valve. The chemical injection line is an independent line that is not affected by the ball valve being
open or closed.
MAIN PARAMETERS
No | Specification | 8" |
1 | O.D. | 203.2mm |
2 | Bore Diameter | 76.5mm |
3 | Length | 2855.5mm |
4 | Working pressure | 103.5Mpa |
5 | Internal pressure strength | 178.3Mpa |
6 | External pressure strength | 257.8Mpa |
7 | Tensile strength | 6299KN |
8 | Torque strength | 137.6KN.m |
9 | Service | H2S,NACE MR0175 |
10 | Working temperature | -29oC+204oC |
11 | Connection thread | 5 3/4-4AS.B 5"-4ACME.B |
Remote Control System
The main function of such system is to control the downhole safety valve in case of emergency situation to shut off
the safety valve.
The system contains Three loop, one loop(1) connects with control line in safety valve,one loop(2) connects with balance line, and rest loop(3) connect with a fusible plug
In case of fire, the temperature on site over 210F, the fusible plug melt, control line loop cut off, the pressure in
system released, push the ball valve in safety valve closed to prevent well in safety situation.
Or if other unexpected happen need to close the well, just pull off the handle of emergency shut down valve, the
hydraulic oil will push safety valve piston forward up, the ball valve will be closed by spring, to prevent the well
Or when do coiled tubing testing, extra force need to be added to shut down safety valve ball valve, the loop 2 will in
work.
There are other option's operation for such system depended on the purpose of testing.
Subsurface control downhole safety valve Inconel
SCSSV downhole safety valve controled by remote control