user login

Polyethylene Anticorrosion Tapes for pipeline

5.0~6.0 USD
Min. Order: 2000 Square Meter
Trade Term: FOB
Payment Terms: L/C, T/T
Supply Ability: 8000 Square Meter/Square Meters / Day
Place of Origin: Guangdong

Company Profile

Location: Guangzhou, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: Heat Shrinkable Sleeves For Telecommunication, PET, Pipeline Anticorrosion

Product Detail

Means of Transport: Ocean, Air
Tensile strength: ≥18MPa
Yield strength: ≥15MPa
Elongation: ≥20%
Dielectric strength: ≥30Mv/m
Peel strength to primed steel plate: ≥25N/cm
Production Capacity: 8000 Square Meter/Square Meters / Day
Packing: According to customers` requirements
Delivery Date: 10-30 days
Show

Product Description

Polyethylene Anticorrosion Tapes are made from a polyethylene and butyl rubber. The installed product provides outstanding adhesion and elastic properties. They are highly adaptive to forces caused by changes in temperature and soil stress creep. They have excellent anti-aging and UV resistance properties.
Specifications
Polyethylene Anticorrosion Tapes for oil,gas,petrochemical, waste water underground and overhead pipelines. The tape shall be applied after the liquid adhensive by hand or with the wrapping mathine.
Resistant to UV
Excellent adhension to pipe and itself
Excellent resistance to cathodic disbonding
Good conformability and sonsistant uniform thickness
Meet ASTM D 1000 standard
Features:
The thickness of the tape ranges from 0.4mm to 1.3mm; the backing thickness ranges from 0.25 to 0.8mm and the adhesive thickness ranges from 0.1 to 0.9mm.
The tape can be used in wide range of temperature: -30℃~80℃.
Good anticorrosion, the tape also enjoys crashworthiness.
Long durability, the tape can be used for 30 years.
Wide application, the tape is suitable for the pipe from 50mm to 1800mm
Repair of pipelines, storage tanks and irregular shapes like flanges, tees, bends, elbows etc.
Cold adhesive tape includes three parts: anticorrosion tape, protective tape, repair tape
Product performance:
item
Anticorrosion tape
Test method
Tensile strength
≥18MPa
GB1040
Yield strength
≥15MPa
GB1040
Elongation
≥20%
GB1040
Peel strength
To primed steel plate
≥25N/cm
GB2792
To back material
5~10N/cm
GB2792
Dielectric strength
≥30Mv/m
GB1408
Volume resistivity
≥1*1012Ω*m
GB1410
Water absorption
≤0.1%
SY0414
Vapor permeability
≤0.2mg/cm³
GB1037
Applicable temperature
5~50℃
Color
Black
Installation
1 General Provisions:
1.1 The installation of anti-corrosion layer should carry out in the temperature 3℃ higher than leak point temperature.
1.2 Primer and adhesive tape should not be applied in sandy situation when there is no reliable protective measure.
2Winding adhesive tape
2.1 The temperature to unwind adhesive tape should be above 5℃.
2.2 In winding, adhesive tape can be used together with primer and those fillers which are compatible with adhesive tape for filling the two sides of weld joints.
2.3 Use appropriate mechanical or hand tools. Painting primer firstly and winding adhesive tape following. The lap length of the starting end and the end of adhesive tape should not less than 1/4 steel pipe circumferential length and should not less than 100mm. The overlapping parts of inner tape and outer tape should be staggered. In winding, the edge of adhesive tape should be parallel, no twist or wrinkle at all.
2.4 In winding adhesive tape in factory, cold adhesive tape can be used directly or after heating. When winding anticorrosion tape, 150mm±10mm weld part should be reserved.
2.5 In winding irregular shaped pipe, repair tape should be a choice, or other special adhesive tape which is better than repair tape in performance. The demand for surface treatment and primer paint of irregular shaped pipe is same as pipe body.
Notice: 1 The number of stacked layers of preformed anticorrosive tubes should follow the principle of "NO DAMAGE TO ANTICORROSIVE LAYER". Different kinds of finished pipe should be stacked separately and soft objects should be placed between anticorrosion pipe layer and at the bottom part to prevent any damage from anticorrosion layer.
2. When load and unload anticorrosion pipe, wide nylon belt or dedicated spreader should be used. Throwing, touching and prying anticorrosion layer are forbidden.
3. Adhesive tape should be stored in a cool and dry place. Avoiding direct sunlight and keeping it away from heat and fire source. It had better be stored in -20~30 ℃.
Post Buying Request