The main technical parameters:
(1)working environment conditions
temperature: -540℃
humidity: ≤95%
barometric pressure : 70.0106kPa
power supply: AC220V_10%;50Hz_1Hz
(2)measuring range :
HC: 010000 10-6(ppm)vol
NO: 05000 10-6(ppm)vol
CO: 010.0 10-2(%)vol
CO2: 020.0 10-2(%)vol
O2: 025.0 10-2(%)vol
rotating speed : 010000rpm
oil temperature: 0120℃
(3)Basic Error :
HC: ±5% CO:±5%
CO2:±5% O2:±5%
NO: ±4%
(4)preheating time : 10Minutes
1.weight: 15Kg
2.Bare machine size:430 * 300 * 190mm
The main function characteristics:
1.Conform to the national standard GB/T18285-2005
2.Adopting infrared absorption spectroscopic method principle,measuring density of HC, CO, CO2, O2, NO of vehicle emissions through the microcomputer analysis
3.Have idle, double idle speed test function
4.Equipped with 7 inch high brightness LCD display, support for multiple language operating menu
5.Automatic calculation, shows excess air coefficientλvalues
6.Equipped with RS-232c digital serial communication interface, convenient networking
7.Equipped with More than 500 groups data storage, and consult functions
8.Equipped with printers, when printing it can be input, output, license plate number
9.the exhaust test is for vehicle with natural gas, liquefied gas and gasoline as fuel
10.Equipped with car power inverter, convenient accessory exhaust inspection
range of application.
Application:
Applicable to Vehicle emissions inspection in the environmental protection department, automobile and motorcycle manufacturers, automobile maintenance enterprises, police station, the transportation testing station and scientific research departments etc.