DSHD-261A Automatic Pensky-Martens Closed Cup Flash Point Tester

1.0~100.0 USD
Min. Order: 1 Set/Sets
Trade Term: FOB
Payment Terms: L/C, T/T
Place of Origin: Guangdong

Company Profile

Location: Zhuhai, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: 4. DUK-2A Multi-Electrode Resistivity Survey System

Product Detail

Means of Transport: Ocean
Brand Name: dshing
Igniting mode: Electric ignition
Packing: wooden case
Delivery Date: 7 days
Show

Product Description

A:Brief description:
    DSHD-261A Automatic Pensky-Martens Closed Cup Flash Point Tester is designed according industrial standard SH/T0315 Technical Specifications of Closed Cup Flash Point Tester.
    The main function of DSHD-261A Automatic Pensky-Martens Closed Cup Flash Point Tester is to make determination of closed cup flash point of the petroleum products according to national standard GB/T 261 or ASTM D93.
B:Main advantages:
  1. Simulation tracking displays function curves of heating up and test time.
  2. Equipped with the English prompt function of mis-operation.
  3. Equipped with prompt function of test date,test time and other parameters.
  4. Automatically calibrate the effect of atmospheric pressure to test and calculate the corrected value.
  5. Differential coefficient detection.Automatically correct the system deviation.
  6. Automatically open the lid,detect the flash point and print test data.
  7. The test arm rises up and lowers down automatically.
  8. Igniting with electric igniting gun,forced air cooling.
C: Main technical specifications and parameters
   1. Power supply:AC(220±10%)V,  50Hz.
   2. Temperature measuring:Measuring range: Room temperature~250℃.
                                        Range of flash point: 41℃~250℃.
                                        Flash point≤104℃: Error 2℃.
                                        Flash point>104℃: Error 6℃.
                                        Resolution: 0.1℃.
                                        Accuracy: 0.5%.
   3. Basic parameters:Heating rate: Correspond with GB/T261
  Igniting mode: Electric ignition(Gas flame 3mm~4mm)
4. Ambient temperature:≤ 40℃
  5. Relative humidity:≤ 80%
  6. Power consumption of overall unit:≤ 350W
D:More Open Cup flash point tester:
DSHD-261 Pensky-Martens Closed Cup Flash Point Tester
DSHD-261-1 Pensky-Martens Closed Cup Flash Point Tester
DSHD-261A Automatic Pensky-Martens Closed Cup Flash Point Tester  
DSHD-261D Fully-automatic Pensky-Martens Closed Cup Flash Point Tester
DSHD-5208 Rapid Closed Cup Flash Point Tester
DSHD-5208A Rapid High-temperature Closed Cup Flash Point Tester
DSHD-5208D Rapid Low-temperature Closed Cup Flash Point Tester
Post Buying Request