user login

GTAKE AC Motor Drive

60.0~10000.0 USD
Min. Order: 1 piece
Trade Term: FOB
Payment Terms: T/T, WU
Supply Ability: 10000per month
Place of Origin: Guangdong

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: AC Motor Drive

Product Detail

Model No.: GK600 SERIES
Means of Transport: Ocean, Air
Structure: Asynchronous Motor
Shape: Linear
Phase: Three Phase
Protect Feature: Waterproof
Speed: Variable Speed
Function: Control
Usage: Industrial
Brand Name: GTAKE
Input terminals: DI-7(HDI-1), AI-3 0~10V, or 0-20mA
Production Capacity: 10000per month
Packing: plywood crate
Delivery Date: 3-35 days
Show

Product Description

 Technical Features of GK600 series
Power input
Rated voltage
3-phaseAC220V/AC230V/AC380V/AC400V/AC415V/AC440V/AC460V/AC480V
1-phase
AC220V/AC230V
Rated input current
See Section 2.3 inuser manual
Frequency
50Hz/60Hz, acceptablefluctuation range ±5%
Allowable range ofvoltage
Continuous voltagefluctuation ±10%, short fluctuation -15%~+10%, i.e. 323V~528V;
Voltage out-of-balancerate <3%, distortion rate as per the requirements of IEC61800-2
Power output
Standard applicablemotor (kW)
See Section 2.3 inuser manual
Rated current (A)
See Section 2.3 inuser manual
Output voltage (V)
3-phase: 0~ ratedinput voltage, Bias < ±3%
Output frequency (Hz)
0.00~ 600.00Hz; unit:0.01Hz
Overload capacity
150% - 1min; 180% -10s; 200% - 0.5s once per 10 minutes
Operationcharacteristics
Control mode
V/f control
Sensor-less vectorcontrol without PG 1
Sensor-less vectorcontrol without PG 2
Range of speedregulation
1:100 ( V/f control,sensor-less vector control without PG 1)
1:200 (sensor-lessvector control without PG 2)
Speed accuracy
±0.5% (V/f control)
±0.2% (sensor-lessvector control without PG 1 & 2)
Speed fluctuation
±0.3% (sensor-lessvector control without PG 1 & 2)
Torque response
< 10ms (sensor-lessvector control without PG 1 & 2)
Starting torque
0.5Hz: 180% (V/fcontrol, sensor-less vector control without PG 1)
0.25Hz: 180%(sensor-less vector control without PG 2)
Basic functions
Start frequency
0.00~ 600.00Hz
Acceleration/decelerationtime
0.00~60000s
Carrier frequency
0.7kHz~16kHz
Frequency commandsource
Digital command +operating panel ∧/∨
Digital command +terminal UP/DOWN
Communication
Analog command(AI1/AI2/EAI)
Terminal pulse command
Motor Started method
Started from startingfrequency
DC braking and thenstarted
Speed search thenstarted smoothly
Motor Stopped method
Ramp to stop
Coast to stop
Ramp stop + DC brake
Basic functions
Dynamic brake capacity
Brake unit actionvoltage: 650V~750V; service time: 0.0~100.0s; brake unit for GK600-4T45G/55Lor below could be internally mounted
DC brake capacity
DC brake startfrequency: 0.00~600.00Hz
DC brake current:0.0~100.0%
DC brake time:0.0~30.00s
Input terminals
Six digital inputterminals (can be extended to 7), one of which can be used for high-speedpulse input. Compatible with active open collectors NPN, PNP and dry contact input
Two analog inputterminals, one of which is voltage/current programmable, and the other isvoltage only (can be extended to 3; extension terminal is voltage/currentprogrammable)
Output terminal
One high-speed pulseoutput terminal, 0~50kHz square wave signal output; can output signals suchas setting frequency and output frequency. etc
One digital outputterminal
One relay outputterminal (can be extended to 2)
One analog outputterminal (can be extended to 2), voltage/current output optional; can outputsignals such as setting frequency and output frequency, etc
Characteristics
Parameter copy,parameter backup, common DC bus, free switching between two motors'parameters, flexible function code displayed & hidden, various main &auxiliary command and switchover, speed searching, a variety ofacceleration/deceleration curves optional, automatic correction of analogvalue, mechanical brake control, 16-step speed control programmable (2-stepspeed supports flexible frequency command), swing frequency controlprogrammable, fixed-length control, counting function, three faults recorded,over excitation braking, over voltage stall prevention, under voltage stallprevention, restart upon power off, hopping frequency, frequency binding,free switching between four sections of acceleration/deceleration time, motorthermal protection, flexible fan control, process PID control, simple PLC,flexible multi-functional key setting, droop control, parameteridentification, weak magnetic control, high-precision torque restraint, V/fseparated control
Protection function
Refer to Chapter VII -Fault Diagnosis and Abnormity Handling
Environment
Place of operation
Indoors, no directsunlight, free from dust, corrosive gases, flammable gases, oil mist, watervapor, water drip or salt content etc.
Altitude
0~2000m
Derating is requiredwhere altitude is more than 1,000m; each increase of 100m in heightcorresponds to a decrease in rated output current by 1%
Ambient temperature
-10°C~50°C
Humidity
5~95%, condensationnot allowed
Vibration
Less than 5.9m/s2(0.6g)
Storage temperature
-40°C~+70°C
Others
Efficiency
Rated power
7.5kW and below: ≥93%
11~ 45kW: ≥95%     55kW and higher: ≥98%
Installation mode
Wall-mounted
Protection level
IP20
Coolingmode  
Forced air cooling
Post Buying Request