user login

Stackable Syringe Pump with Drug Library

500.0~5000.0 USD
Min. Order: 1 Piece/Pieces
Payment Terms: L/C, T/T, WU

Company Profile

Location: Hong Kong
Business Type: Manufacturer, Trading Company
Main Products: Fetal Heart Rate Monitor, Doppler Detector Baby Monitor, Ultrasonic Transducer Ultrasonic Monitor, Neurocare Series Patient Monitor, Fetal Monitor Maternal Monitor

Product Detail

Model No.: NC-SP1800Y
Means of Transport: Ocean, Air, Land
Brand Name: NEUROCARE
Packing: CARTON
Show

Product Description

 
Features
1. Compatible with syringes from (2/3ml), 5ml,10ml,20ml,30ml,50ml,60ml.
2. Stackable to be the maximum 8 channels.
3. High accuracy +/-2% after correct calibrated.
4. Three work modes: Rate mode, Time mode and Weight mode.
5. Bolus / Purge, KVO function.
6. With drug libraries:10 categories of common drugs,1030 kinds in total.
7. History recorded, real time displayed.
8.  6 hours continuous work after fully charged.

Specification
PARAMETER
SPECIFICATION
Applicable syringes
5ml,10ml,20ml,30ml,50ml,60ml of any standard
Accuracy
+/- 2% with correct calibration
Rate mode
50ml(60ml):0.1ml/h-1800.0ml/h (0.1ml/h step)
20ml(30ml):0.1ml/h-800.0ml/h (0.1ml/h step)
10ml:0.1ml/h-400.0ml/h (0.1ml/h step)
5ml (2/3ml): 0.1~200ml/h (0.1ml/h step)
(Programmable 0.01ml/h~9999.9ml/h)
Time Mode
SOL. VOL:0.1-999.9ml (0.1ml step)
TIME:1-1999min (1min step)
Body Weight Mode:
Volume:0.1-999.9ml(0.1ml step)
DRUG MASS:0.1-999.9mg 0.1mg step)
DOSE:0.01-99.99ug/kg/min(0.01ug/kg/min step)
WEIGHT:0.1-300kg(0.1kg the least step)
Total Volume Range
0.1-1999.9ml (0.1 ml step)
Purge Rate
50ml(60ml):1800.0ml/h,
20ml(30ml):800.0ml/h,
10ml:400.0ml/h, 5ml (2/3ml): 200ml/h
Programmable and adjustable
KVO Rate
1ml/h
Occlusion pressure
Three level setting LOW, MEDIUM or HIGH
Alarms
Near empty, Syringe empty, Volume complete (when limit volume is set), Occlusion, Syringe loose, Operation error, Low battery, device failures.
Three levels of alarm volume LOW, MEDIUM or HIGH
Bolus Rate
5ml: 10~200ml/h,10ml:10-300ml/h,20ml(30ml):10-600ml/h,
50ml(60ml):10-1200ml/h
Programmable and adjustable
Bolus Volume
Maximum of 25ml
Interface
RS-232  (Reserved port)
Power source
AC power supply: AC 100 to 240V( +/-10%),50/60Hz;
Built-in Lithium Battery: Rechargeable, 11.1V, 2000mAh.
6 hours of continuous operation
Accessories:
AC power line, Operational manual
Protection Class
Class I, Type CF,IPX4
Dimension / Net weight
230mm*150mm*125mm , 2.0kg



















Post Buying Request