1500VA Power Disinfection Machinery with Dry Function/Hospital Rapid Degassing Facility with Three Testing Way
1-Main Features
a.According to Europer B standard,with 3 times pre-vacuum
b.The water setting is full-automatic
c.Can show the reason of failure on LCD, do not need to check recording to code menu
d.Safety Devices:
(1).Over heat control:When inner temperature is overheated,power will be shut down
automatically and alarm system
(2). Over pressure control: it have alarm system when over pressure.
(3).Safety door lock system
(4).Low water level indictor:It have alarm system when low water.
2-General Safety Recommendations
v The user is responsible for proper operation and maintenance of the sterilizer in accordance with the instructions listed in this manual.
v The sterilizer could not be used for liquid.
v The sterilizer could not be used for gas.
v The trays and the load will still be hot at the end of each cycle. Use the tray holder to remove each tray from the chamber.
v Do not open the door of the chamber during the sterilization programs.
v Do not put you hands or face on the cover of the water tank when the sterilizer is running.
v Do not remove the instruction plate or any label from the sterilizer.
v Do not pour water or any other liquid over the sterilizer.
v Do not fill the caustic liquid into the water tank.
v Do not fill the caustic matter in the chamber.
v Use only high quality distilled water.
v Unplug the mains lead before inspecting or servicing the machine.
v Only an approved technician using original spare parts can carry out repairs and maintenance.
v In case of transportation, drain both water tanks completely, allow the sterilization chamber to cool down and preferably use the original packaging.
v The articles under sterilization should be removed by special tools when the temperature over 40℃.
v Picking-up the sterilizing trays should use the special tools provided.
v During the transportation, the
sterilizer should be carried by two people in case of turning over.
v Notice! This product can't be put on the place that is not easy to cut off power supply.
v Prohibit covering the lid of water tank during usage.
3- Products data
Electronic Control microprocessor
Programs 8
Test method 3
Cycle recording Yes
Steel chamber AISI 304
Temperature sensors in chamber1
Vacuumpump Dual head
Water pump 1 ULKA water pump
Tank sensor 2,used water sensor & distilled water sensor
Safety feature Electric-Mechanical dual interlock, Mechanical safety valve, alarms when door opened, Water level control, over heating control, over pressure protection, error messages viewed on the display
Alarm indications 10
Conformity 93/42/EEC, EN 13060, EN 61010
4- Packing details
Item Nr. | Power | Chamber size | Unit size | Packing size | Weight |
Novo B+ 12 | 1400W | 12L=192X340mm | 560X450X400 | 660X525X495 | 43 |
5- Payment details
T/T, L/C & west union acceptable.
6- Shipment
Express: Below 1pcs samples testing, express recommended.e.g: TNT,DHL,UPS etc. Shipping days 3-5days.
Air shipment: Between 1pcs and 2pcs, Normal air shipment recommended. Shipping days 5-10days.
Sea shipment: More than 4pcs, Nor sea shipment recommended. Shipping days around 30days.