user login

pon OTDR

Min. Order: 1 Piece/Pieces
Trade Term: FOB
Payment Terms: L/C, D/P, D/A, T/T, WU
Supply Ability: 1000
Place of Origin: Shandong

Company Profile

Location: Qingdao, Shandong, China (Mainland)
Business Type: Manufacturer
Main Products: OTDR, Fiber Fusion Splicer, Optical Power Meter, Digital Transmission Analyzer And So On

Product Detail

Model No.: JX8002
Means of Transport: Air
Brand Name: E-JIAXUN
Production Capacity: 1000
Packing: Appropriative plastic case,and two paper bags outside,1KG in gross weight.
Delivery Date: One day after payment is confirmed
Show

Product Description

Mainly features:
ο Handheld\lightweight and convenience for carrying
ο 45dB high dynamic range
ο ≤0.8m extra-short event dead zone
ο 0.05m high distance resolution,128k sampling points
ο With automatic measurement mode,one-button operating
ο Test up to four wavelengths with a single unit
ο Communication light check automatically
ο Remote communication control via Ethernet
ο Double USB interfaces, supporting USB stick and printer and direct cable download to PC via ActiveSync
ο Supporting Bellcore GR196 file format in writing or reading
ο Built-in lithium battery with high capacity for over 8 hours of operating life
ο Visible fault locating (VFL) and optical power meter
ο Universal FC/PC,FC/SC,FC/ST connector type, it's convenient for surface cleaning
ο Unique function of updating application software on-line
Extra-short event dead zone
Due to its high resolution,JX8002-3103   OTDR has 1m extra-short event dead zone, which is suitable for testing short optical fiber and pigtail optical fiber.
JX8002 -3103 can quickly determine and locate the events and faults in trace precisely, then lists all events in even table, so it's very useful to maintainers to improving efficiency and it's unnecessary to know about the relative background knowledge.
High-speed auto measurement
The function of auto measurement of JX8002-3103 OTDR makes it unnecessary to operator to know about the further details of operating. The operation becomes very simple: after connect the fiber, only press[Start],then the trace measured is displayed and the events are listed on screen in a few seconds, now, you can view the trace and event table.

Unique PON testing capability
JX8002-3103 is ideal for access and FTTH network testing, it enable you to test through 1x32 even 1x64 splitters for PON(passive optical network) testing.
JX8002 -3103 offers an exceptional 1m event dead zone and 0.05m high distance resolution, with which you can characterize all events between the transmitter and the central office's fiber distribution panel.

Convenient VFL function
he built-in 650nm visual fault locator (VFL) is ideal for identifying bad splice, bad connector, break or macro bend easily. The standard VFL with more than 2 milliwatt output power is factory installed in JX8002-3103 , which the operation distance is in excess of 5 kilometers.
Communication Light Check
When measuring a fiber in service, the measuring result by an OTDR is not precise, and there is a potential risk of permanent damage to the internal photoelectric of OTDR receiver. To prevent these problems, JX8002 -3103
-3103 Multiple Wavelengths and Models
JX8002-3103 OTDR can provide any of single mode or multimode or both, designed to test FUT at up to four wavelengths in single unit, such as 850, 1300, 1310, 1383, 1490, 1550, 1625 and 1650nm wavelengths, with which JX8002 -3103
Abundant external interface
has abundant external interface, such as USB, Min-USB, Ethernet, earphone and SD, due to these, it can provide the following functions:
ο Training via multimedia for operators, which can enable you become a measuring expert within short time.
ο Implementing remote controlling through Ethernet, troubleshooting from long distance for fiber under test.
ο Printing trace and event table JX8002-3103 ο Updating application software on-line

Typical application:
JX8002-3103 OTDR is mainly used to measure FTTx network, it provides multifunctions in one unit. JX8002-3103 offers three measuring modes: manual mode (including real time mode and average mode), auto mode and dead zone mode.
Manual measurement mode: manual mode is suitable for skilled operator who is familiar with the instrument. In this measurement mode, to get more accurate results, real-time mode or average mode can be selected if necessary.
In real-time mode, the dynamic changes of fiber chain can be detected timely, it is very useful when you need to observe the effect and process of fiber being spliced or connected.
In average measurement mode, the noise in trace can be suppressed, and the SNR(signal noise ratio) is improved, therefore,the result is more accurate. In fact, the more average times is executed, the more noise in trace is suppressed, and the longer time is spent for signal processing. In practice, the average times should be set properly according to necessity.
Auto measurement mode: the optimized measurement conditions are set automatically, it's unnecessary to operator to know about the complicated background knowledge and the further details of operating. In this mode, the more accurate results can be gained when proper average times are set, but it will increase the time of signal processing.
Dead zone mode: this mode is suitable for testing optical fiber with short distance and the optimized settings of distance range, pulse width and attenuator can be executed automatically. To get the best result, the terminal return loss should be guaranteed less than -40dB.
General Specifications:
Dynamic rangePlease refer to "OTDR modules specifications"
Distance uncertainty±(0.75m + sample space + measurement distance×0.0025%)1
Sampling resolution0.05,0.1,0.2,0.5,1,2,4,8,16m
Distance range0.4,0.8,1.6,3.2,6.4,16,32,64,128,256,512km(SMF);
0.4,0.8,1.6,3.2,6.4,16,32 (MMF of 850nm)
Pulse width5,10,30,80,160,320,640,1280,5120,10240,20480ns
5,10,30,80,160,320,640,1280 (MMF of 850nm)
Loss threshold0.01dB
Sampling pointsUp to 128k
Linearity0.05dB/dB
Loss resolution0.001dB
Memory capacity≥800traces(build-in), ≥65500traces(2GB SD storage)
Group refractive index setting1.00000 to 2.00000 (0.00001steps)
Distance unitkm,m,kft,ft
Display640×480, 6.5 inch TFT-LCD (touch screen)
InterfaceUSB, Min-USB, Ethernet, earphone, SD
Optical connectorFC/SC/ST (universal connector)
VFL650nm±10nm,2mW(typical);CW/1Hz
Optical Power MeterWavelength range: 1200nm to 1650nm Measurement range: -60 to 0dBm Measurement accuracy: 5%(-10dBm, CW)
Power supplyAC adapter 100 to 240V, 50/60Hz, 1.5A DC:19V±2V(2A) Built-in Lithium battery: 4400mAh, operating time ≥8 hours 2
LanguageUser selectable: simplified Chinese, English, Russian, Korean etc.. (please contact CETC 41st for others)
EnvironmentOperating temperature: -10 to 50℃(charging:5 to 40℃)
Storage temperature: -40 to 70℃(Battery: -20 to 60℃)
Relative humidity: 5% to 95%, non-condensing
Dimensions295×186×75(mm)
Weight2.5kg Approx.




Note1: Does not include uncertainty due to fiber index
Note2: Low brightness, exclude measuring.
Ordering information:
ο Specify base unit
Ordering NO.Description
JX8002 -3103-SSJX8002-3103 base unit with standard display brightness
JX8002-3103 -HSJX8002-3103 base unit with enhanced display brightness




Note: the standard OTDR interface type is FC/UPC,type of FC/APC is optional.
ο Standard accessories
NO.NameNO.
1Power line1
2AC/DC adapter2
3Quality certification3
4User manual4
5Trace analyzing software(CD)5
6Hard Carrying case(including gallus)6
7Special gallus of instrument7




ο OTDR modules specifications1
Ordering numberOperating wavelengthFiber typeDynamic Range2(dB)Event Dead zone3(m)Attenuation dead zone(m)
JX8002 -11011310nmSMF45210
JX8002 -11021550nm43210
JX8002 -11031625nm38110
JX8002 -11041625nm(build-in filter)36110
JX8002 -11051650nm38110
JX8002 -11061650nm(build-in filter)36110
JX8002 -11071490nm36110
JX8002 -11081383nm36110
JX8002 -1201850nmMMF262.515
JX8002 -12021300nm36213
JX8002 -21011310/1550nmSMF42/402/210/10
JX8002 -21021310/1550nm40/381/110/10
JX8002 -21031310/1550nm37/351/110/10
JX8002 -21041550/1625nm38/381/110/10
JX8002 -21051550/1625nm(build-in filter)36/361/110/10
JX8002 -21061550/1650nm38/381/110/10
JX8002 -21071550/1650nm(build-in filter)36/361/110/10
JX8002 -21081310/1550nm45/431/110/10
JX8002 -2201850/1300nmMMF26/362.5/215/13
JX8002 -31011310/1490/1550nmSMF39/34/381/1/110/10/10
JX8002 -31021310/1550/1625nm39/38/361/1/110/10/10
JX8002 -31031310/1550/1625nm(build-in filter)37/36/341/1/110/10/10
JX8002 -31041310/1550/1650nm39/38/361/1/110/10/10
JX8002 -31051310/1550/1650nm(build-in filter)37/36/341/1/110/10/10
JX8002 -4001850/1300/1310/1550nmSMF/MMF24/34/34/342/2/1/115/13/10/10
JX8002 -41011310/1490/1550/1625nmSMF35/32/34/341/1/1/110/10/10/10
JX8002 -41021310/1383/1550/1625nm35/32/34/341/1/1/110/10/10/10




Note1: one and only one module of above must be selected.
Note2: pulse width 10240ns, average times≥300,SNR=1,23℃±2℃;
Note3: dead zone mode, distance range: ≤3.2km, Pulse width: 5ns, terminal reflection loss:≥ 40dB, typical;
ο Options
NO.Nametypenote
1USB stick
Saving measuring data
2SD
Saving measuring data
3printerHP LJ P2015D or HP LJ 1022Printing traces
4USB cable
Communicating with PC
5Standby battery pack6417LB-1192Standby battery
6FC/SC,FC/ST connectors





Note:For the necessity of improvement, the material contained in this document is subject to change without notice.
ο Standard accessories
NO.Namequantity
1Power line1
2AC/DC adapter1
3Quality certification1
4User manual1
5Trace analyzing software(CD)1
6Hard Carrying case(Including gallus)1
7Special gallus of instrument1




Note: the standard OTDR interface type is FC/UPC,type of FC/APC is optional.

Post Buying Request