(2)Single key intelligent switching, easy to operated
(3)Output short circuit protection (when the inverter is working on battery mode): when there is short circuit, the inverter will indicate it and the machine will shut down automatically.
(4)Overload protection: when there is overload, the machine will prompt you and protect the inverter from being damaged automatically. Over 100%-120%, inverter shuts down 30s later, over 150%, inverter shuts down at once.
(5)Internal circuit can protect the battery .when the battery voltage is under the 15% level,the inverter will be shut down at once.
1.LCD display
2.LINE City Power light: if the machine works normally on city power made, the lamp will be always on; if the machine is off and city power is normal, the lamp will flash and it indicates that the machine is charging automatically.
3.INV lighting means inverter circiut working well;
4.CHA battery recharge
5.Fault when
inverter work mistake, it will flash
6.ON/ OFF Manual turn on/button