Min. Order: | 10 Units |
---|---|
Trade Term: | FOB |
Payment Terms: | Credit card, T/T, WU |
Supply Ability: | 1000 units per week |
Place of Origin: | Zhejiang |
Location: | Ningbo, Zhejiang, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | SCG353A047 1 1/2 0.35-0.85Mpa ASCO Pulse Jet Vave, 2 Way Solenoid Valve, 2 SCG353A050 ASCO Diaphragm Impulse Valves |
Model No.: | CA-45DD RCA-45DD |
---|---|
Means of Transport: | Ocean, Air, Land |
Power: | Pneumatic |
Standard or Nonstandard: | Standard |
Pressure: | Low Pressure |
Structure: | Diaphragm |
Material: | Casting |
Temperature of Media: | Normal Temperature |
Media: | Gas |
Brand Name: | Others |
Production Capacity: | 1000 units per week |
Packing: | Plastic bags,Boxes,cartons or Customer's request |
Delivery Date: | within 15 working days after payment |
Product Name: GOYEN 1 1/2" CA-45DD RCA-45DD Dual stage pulse valve
Description
High performance diaphragm valve with threaded ports. Available with integral pilot or as remotely piloted valve. Outlet at 90° to inlet.
Suitable for
Dust collector applications, in particular for reverse pulse jet filter cleaning including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters.
Construction
Body: Aluminium (diecast)
Ferrule: 304 SS
Armature: 430FR SS
Seals: Nitrile or Viton (reinforced)
Spring: 304 SS
Screws: 302 SS
Diaphragm Seat: PA-6 (standard), Viton coated mild steel or High Density PE Refer to Q Series Solenoid product data sheet for solenoid construction details.
Operation
Recommended on time range: 50-500ms
Recommended time between pulses: 1 minute or greater
Maintenance
Before conducting any maintenance activity on the system ensure that components are fully isolated from pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled. Diaphragm and pilot inspection should be conducted annually.
Approvals
Integrally piloted valves meet the requirements of:
. Atex II 2D Mechanical
. CSA (C&US)
C22.2 No. 139-1982 UL Std No. 429
. C-Tick - integral pilots
. EMC (89/336/CE) - integral pilots
Installation
1. Prepare supply and blowtube pipes to suit valve specification. Avoid installing valves underneath the tank.
2. Ensure tank and pipes are free from dirt, rust or other particulate.
3. Ensure supply air is clean and dry.
4. Mount valves to inlet pipes and blowtube to valves, ensuring no excess thread sealant can enter the valve itself.
5. Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only).
6. Apply moderate pressure to system and check for installation leaks.
7. Fully pressurise system.
8. Test fire and listen for proper actuation and crisp pulse noise.
Voltage: DC12V,DC24V,AC36V,AC110V,AC220V,AC380V
Pressure Range: 30(5)-860(125) kPA(Psi)
Temperature Range: Nitrite Seals: -40°C (-40°F) to 82°C(179.6°F) Viton Seals: -29°C (-20.2°F) to 232°C (449.6°F)
Outside Diameter,Weights Product Characteristics and Performance:
NOM.SIZE | Port Size | OD mm | CA Integral Pilot(CA)Kg(lbs) | RCA Integral Pilot(CA)Kg(lbs) | Flow KV CV | Diaphragm Number |
25 | 1" | 33.4 | 1.21(2.67) | 0.99(2.18) | 20 23 | 1 |
45 | 1.5" | 48.3 | 2.28(5.03) | 2.11(4.65) | 44 51 | 2 |
Diaphragm Kits | ||
Model | Nitrile | Viton |
CA/RCA-20DD | K2000 | K2007 |
CA/RCA-25DD | K2501 | K2503 |
CA/RCA-45DD | K4501 | K4503 |
Dimension(mm and inch):