Electrical Specvifications |
| Model | APS1000W | APS1500W | APS2000W | APS3000W | APS4000W | APS5000W | APS6000W |
Inverter Output | Continuous Output Power | 1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W |
Surge Rating(20s) | 3000W | 4500W | 6000W | 9000W | 12000W | 15000W | 18000W |
Output Waveform | Pure Sine wave/Same as input(Bypass mode) |
Nominal Efficiency | >88%(Peak) |
Line Mode Efficiency | >95% |
Power Factor | 0.9-1.0 |
Nominal Output Voltage rms | 100-110-120Vac / 220-230-240Vac |
Output Voltage Regulation | ±10% RMS |
Output Frequency | 50Hz ± 0.3Hz/60Hz ± 0.3Hz |
Short Circuit Protection | Yes( 10s after fault ) |
Typical transfer Time | 10ms(Max) |
THD | < 10% |
DC Input | Nominal Input Voltage | 12.0Vdc |
( *2 for 24Vdc, *4 for 48Vdc) |
Minimum Start Voltage | 10.0Vdc |
Low Battery Alarm | 10.5Vdc / 11.0Vdc |
Low Battery Trip | 10.0Vdc / 10.5Vdc |
High Voltage Alarm | 16.0Vdc |
Low Battery voltage recover | 15.5Vdc |
Idle Consumption-Search Mode | < 25 W when Power Saver On |
Charger | Output Voltage | Depends on battery type |
Charger Breaker Rating | 10A | 15A | 20A | 20A | 20A | 30A | 30A |
Max Charge Rate | 35A / 70A |
Battery Initial Voltage for Start Up | 10-15.7V for 12V( *2 for 24V, *4 for 48V) |
Over Charge Protection Shutdown | 15.7V for 12V (*2 for 24V, *4 for 48V) |
Charger curve(4 stage constant current) 4 step digital controlled progressive charge | Battery types ( *2 for 24Vdc, *4 for 48Vdc) |
Remote Control | Yes. Optional |
Bypass & Protection | Input Voltage Waveform | Sine wave (Grid or Generator) |
Nominal Voltage | 110Vac | 120Vac | 220Vac | 230Vac | 240Vac |
Max Input AC Voltage | 150VAC | 270VAC |
Nominal Input Frequency | 50Hz or 60Hz (Auto detect) |
Low Freq Trip | 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz |
High Freq Trip | 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz |
Overload protection(SMPS load) | Circuit breaker |
Output Short circuit protection | Circuit breaker |
Bypass breaker rating | 10A | 15A | 20A | 30A | 30A | 40A | 40A |
Transfer switch rating | 30amp for UL & TUV | 40amp for UL |
Bypass without battery connected | Yes |
Max bypass current | 30amp | 40amp |
Bypass over load current | 35amp: Alarm | 45amp: Alarm |
AVR Function | Input AC Voltage Range | 90-140V±4% | 154-253V±4% |
Stabilized Output Voltage rms | 120VAC±10% rms | 230VAC±10% rms |
Nominal Voltage | 110Vac | 120Vac | 220Vac | 230Vac | 240Vac |
(A) Line Low loss N/W (On Battery) | 84/72 | 92/78 | 168/143 | 176/150 | 183/156 |
(B) Line Low comeback N/W (On Boost) | 89/77 | 97/83 | 178/153 | 186/160 | 193/166 |
(C) Line 2nd boost threshold (On Boost) | ** | ** | ** | ** | ** |
(D) Line 2nd boost comeback (On Boost) | ** | ** | ** | ** | ** |
(E) Line 1st boost threshold (On Boost) | 99 | 108 | 198 | 207 | 216 |
(F) Line 1st boost comeback (On Normal) | 103 | 112 | 205 | 215 | 225 |
(G) Line buck comeback (On Normal) | 118 | 128 | 235 | 246 | 256 |
(H) Line buck threshold (On Buck) | 121 | 132 | 242 | 253 | 264 |
(I) Line high comeback (On Buck) | 127 | 139 | 253 | 266 | 278 |
(J) Line high loss (On Battery) | 132 | 144 | 263 | 276 | 288 |
Mechanical Specifications | Mounting | Wall mount |
Inverter Dimensions(L*W*H) | 382*218*179mm | | 442*218*179mm | 598*218*179mm |
Inverter Weight | 18KG | | 20KG | 24KG | 35KG | 45KG | 45KG |
Shipping Dimensions(L*W*H) | 520*315*300mm | | 580*315*300mm | 740*315*300mm |
Shipping Weight | 20KG | | 22KG | 26KG | 37KG | 47KG | 47KG |
Display | Status LEDs / Status LEDs+LCD |
Standard Warranty | 1 Year |