Product Description

Applications:
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between
the primary circuit (high power) and the secondary circuit (electronic circuit).

Main technical data:
1. Primary normal current IPN: +/-3000A       
2. Primary current measuring range IP: 0~ +/-3300A                        
3. Supply voltage(+/-5%): +/-15V
4. Current consumption: 25mA+ Secondary output voltage /loading resistance
5. Isolation test: Between the primary circuit to the secondary circuit(+.-.M): 2.5kVrms/50Hz/1min
6. Normal output voltage @RL=10kΩ,TA=+25 C: +/-10V
7. Loading resistance: more than 3.3kΩ

Accuracy – Dynamic performance Data
1. Accuracy @TA=+25 C:
±1% (measuring current @ 0~±2250A);  ±15% (measuring current @±2250~±3300A)
2.   Non-linearity (0~ IPN): +/-1% (Measuring current @ 0~±2250A)
3. Electrical offset voltage VOE, TA=+25 C : +/-30mV
4. Hysteresis offset voltage @ IP=0,
after an drift of 1x IPN: less than +/-30mV
5. Thermal drift of VOE:   less than +/-1 mV /K
      6.   Thermal drift of the gain (% of reading): less than +/-0.1%/K
7.   Response time (@ 90% of IP): not more than 10us
8. di/dt:>100A/us
9.   Frequency bandwidth (-0.5dB): DC 0~50 kHz

General data:
1. Operating temperature: -40 C ~+85 C
2. Storage temperature: -40 C ~+85 C
3.   Weight: approx. 230g
4.   Standards: EN 50155

Features:
1. Hall effect measuring principle
2. Galvanic isolation between primary and secondary circuit
3. Insulated plastic case made of white PPO recognized according to UL 94-V0  

Dimension:
NCA1A-3000A Current Transducer
Connection:
NCA1A-3000A Current Transducer