user login

NVCL.200D-22 Voltage Transducer

Min. Order: 1000 Piece/Pieces
Payment Terms: T/T
Supply Ability: 10000 Piece/Pieces per Month
Place of Origin: Zhejiang

Company Profile

Location: Ningbo, Zhejiang, China (Mainland)
Business Type: Manufacturer, Trading Company, Agent, Distributor/Wholesaler

Product Detail

Model No.: NV25-200V
Means of Transport: Ocean
Output: Switching Transducer
Theory: Hall Sensor
Usage: Level Sensor
Primary normal voltage: 200V
Production Capacity: 10000 Piece/Pieces per Month
Packing: According to customer's request
Delivery Date: 15 --20 days
Show

Product Description

NV25-200V Voltage Transducer

Applications:                                            

For the electronic measurement of voltages: AC, DC IMPL.,etc.,with galvanic isolation between the primary (high voltage) and the secondary (electronic) circuits.

Main technical data:

1. Primary normal voltage VPN: 200V r.m.s

2. Measuring resistance:               RMmin    RMmax

with +/-12V   @±VN max :   30 ohm     200 ohm

                       @±1.5×VN:    30 ohm     100 ohm

with +/-15V   @±VNmax:     100 ohm     320 ohm

                       @±1.5×VN:    100 ohm     180 ohm

3. Primary voltage, measuring range VP: 0~+/-300V

4. Secondary nominal output: 25mA rms

5. Conversion ratio: 2500:1000

6. Supply voltage(+/-5%): +/-12V~+/-15V                       

7. Current consumption (@±15V):10mA + Secondary output current

8. Isolation test: Between the primary circuit and the secondary circuit: 4.1kVrms/50Hz/1min

Accuracy – Dynamic performance data:

1. Accuracy @ VPN, TA=+25 oC: +/-0.8%

2. Non-linearity @ VPN, TA=+25 oC: +/-0.2%

3. Offset current ≤±0.15mA(@+25℃)

4. Thermal drift:   +/-0.6mA(-25oC ~+25 oC)

+/-0.35mA(-25oC ~+70 oC)

5. Response time: not more than 15us

General data:

1. Operating temperature: -25ºC~+70ºC

2. Storage temperature: -40 oC ~+85 oC

3. Primary resistance : 20kilohm

4. Secondary coil resistance: not more than 110 ohm

5. Weight: 70g×(1±20%)g

6. Standards: EN50155

Features:

1. Hall effect measuring principle

2. Galvanic isolation between primary and secondary circuit

Dimension:

Connection:
NV25-100V Voltage Transducer



Post Buying Request