user login

NVCT.100-13 Voltage Transducer

Min. Order: 1000 Piece/Pieces
Payment Terms: T/T
Supply Ability: 10000 Piece/Pieces per Month
Place of Origin: Zhejiang

Company Profile

Location: Ningbo, Zhejiang, China (Mainland)
Business Type: Manufacturer, Trading Company, Agent, Distributor/Wholesaler

Product Detail

Model No.: NCV1-150/SP3
Means of Transport: Ocean
Output: Switching Transducer
Theory: Hall Sensor
Usage: Level Sensor
Primary normal voltage: 150V
Production Capacity: 10000 Piece/Pieces per Month
Packing: According to customer's request
Delivery Date: 15 --20 days
Show

Product Description

NCV1-150/SP3 Voltage Transducer

                                       

For the electronic measurement of voltages: AC, DC IMPL.,etc.,with galvanic isolation between the primary (high voltage) and the secondary (electronic) circuits.

Main technical data:

1. Primary normal voltage VPN: 100V r.m.s

2. Primary voltage, measuring range VP: 0~+/-150V

3. Secondary nominal output: 50mA r.m.s

4. Measuring resistance:                         RMmin    RMmax

with +/-15V~+/-24V   @ +/-100V max:  0 ohm      10 ohm

                             @ +/-150V max: 50 ohm      100 ohm

5. Supply voltage (+/-5%): +/-15V~+/-24V

6. Current consumption: ≤45mA (@±24V)+ Secondary output current                      

7. Isolation test: Between the primary circuit and the secondary circuit(+.-.M): 6kVrms/50Hz/1min

Accuracy – Dynamic performance data:

1. Accuracy @ VPN, TA=+25 oC: +/-1%

                   -40 oC~+85 oC: +/-3%

2. Non-linearity @ VPN, TA=+25 oC: better than +/-0.1%

3. Offset voltage @ VP=0, TA=+25 oC: not more than +/-0.25mA

VP=0, TA=-40 oC~+85 oC: not more than +/-0.75mA

4. Response time @90% of VPN: about 4us

5. Frequency bandwidth (-3dB): DC to 15kHz

General data:

1. Operating temperature: -40ºC~+85ºC

2. Storage temperature: -45 oC ~+90 oC

3. Total primary power loss: 2W

4. Primary resistance @ TA=+25 oC: 5 kΩ

5. Weight: 420g

6. Standards: EN 50155

Features:

1. Close loop (compensated) voltage transducer

2. Galvanic isolation between primary and secondary circuit

3. Insulated plastic case made of black PC recognized according to UL 94-V0

Dimension:

Connection:

Post Buying Request