FL Series
Specifically designed for fluorescent lights
Suitable for industrial environments
UL Listed for aftermarket installation
Ordering Information
Specifications
Maximum leakage current, each Line to Ground: |
| @ 125 VAC 60 Hz | 3.0 mA |
| @ 280 VAC 50 Hz | 6.0 mA |
| | |
Hipot rating (one minute): |
| Line to Ground | 1560 VAC |
| Line to Line | 1560 VAC |
| | |
Operating Frequency: | 50 / 60 Hz |
| | |
Rated voltage: | 125 / 280 VAC |
| | |
Rated Current: | 3.9 Amps |
|
Operating Ambient Temperature Range (at rated current Ir): |
| | -10°C to +40°C |
In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir √(85-Ta)/ |
Available Part Numbers
Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.
Electrical Schematic
Case Styles
Case Dimensions
Part No. | A | B | C | D | E |
(max.) | (max.) | (max.) | ± .015 | (max.) |
± .38 |
3FL3 | 3.35 | 2.07 | 1.16 | 2.938 | 2.57 |
85.09 | 52.58 | 29.5 | 74.63 | 65.3 |
Performance Data
Typical Insertion Loss |
Measured in closed 50 ohm system |
|
3FL3 |
Minimum Insertion Loss in dB: |
Measured in closed 50 ohm system |
| | |
Differential Mode / Symmetrical (Line to Line) | | |
| | |
Current Rating | Frequency - MHz | .15 | .3 | .6 | 1 | 4 | 10 | 20 |
| 3.9 A | 10 | 18 | 34 | 46 | 56 | 38 |
|