user login

F7358 Corcom 30VK6 TE 2-1609028-0 2-6609028-0

Min. Order: 1 Piece/Pieces
Trade Term: FOB
Payment Terms: L/C, T/T
Supply Ability: 1234567890
Place of Origin: Shanghai

Company Profile

Location: Shanghai, China (Mainland)
Business Type: Manufacturer, Trading Company, Agent, Distributor/Wholesaler, Service
Main Products: Corcom Filter CU Series (1-15 Amp), EMI Filter Corcom Accessory Outlet Filter(EBF Series ), TE Corcom/RFI Power Line Filters/B Series (1-30 Amp), RFI Power Line Filters EC Series (1-10 Amp)

Product Detail

Model No.: 30VK6
Means of Transport: Ocean, Air
Type: EMI Filter
Brand Name: TE Corcom
Rated Current: 1 to 80A
Production Capacity: 1234567890
Packing: 16EA/BOX
Delivery Date: 35 days
Show

Product Description

  • Suitable for high impedance loads
  • Well suited to applications where pulsed, continuous and/or intermittent RFI interference is present
  • EK models meet the very low leakage current requirements for VDE portable equipment and non-patient care medical equipment
  • Available with ground line inductor (choke)
  • product name : Power Line Filters
    K Series
    1.Suitable for high impedance loads
    2.Well suited to applications where pulsed, continuous and/or intermittent RFI interference is present
    3.EK models meet the very low leakage current requirements for VDE portable equipment and non-patient care medical equipment
    4.Available with ground line inductor (choke)
    Ordering Information

    *1-15A: IEC 60320-1 C14 inlet mates with C13 connector
    20VK7: C20 inlet mates with C19 connector
    Specifications
    Maximum leakage current, each Line to Ground:
    VK ModelsEK Models
    @ 120 VAC 60 Hz.5 mA.21 mA
    @ 250 VAC 50 Hz1.0 mA.36 mA
    Hipot rating (one minute):
    Line to Ground2250 VDC
    Line to Line1450 VDC
    Operating Frequency:50 / 60 Hz
    Rated voltage (max.):250 VAC
    Rated Current:1A to 60A
    20VK7 VDE approved to 16 Amps
    Operating Ambient Temperature Range (at rated current Ir):
    -10°C to +40°C
    In an ambient temperature (Ta) higher than +40°C
    the maximum operating current (Io) is calculated as
    follows: Io = Ir √(85-Ta)/45

    Electrical Schematics


    30 & 40VK6C


    60VK6


    Accessories
    GA400: NEMA 5-15P to IEC 60320-1 C13 line cord

    Case Styles

    K1 (1, 2, 3, 6, 10A)

    Typical Dimensions:
    Line/Load Terminals(4):.250 [6.3] with .07 [1.8] Dia. hole
    Ground Terminal(1):.250 [6.3] with .07 x .16 [1.8 x 3.8] slot
    Mounting Holes (2):.188 [4.75] Dia.
    K1 (20A)


    Typical Dimensions:
    Line/Load Terminals(4):.250 [6.3] with .07 [1.8] Dia. hole
    Ground Terminal(1):.250 [6.3] with .07 x .16 [1.8 x 3.8] slot
    Mounting Holes (2):.188 [4.75] Dia.
    K3


    Typical Dimensions:
    Wire leads (5):.4.0 [101.6] Min. AWG18 (AWG16 for 10A)
    Mounting Holes (2):.188 [4.75] Dia.
    10VK6


    Typical Dimensions:
    Terminals (5):8-32
    Torque 18 lbf-in. [2.03 N-m] max. ±2[.22]
    Mounting Holes (2):.188 [4.75] Dia.
    20VK6


    Typical Dimensions:
    Terminals (5):8-32
    Torque 18 lbf-in. [2.03 N-m] max. ±2[.22]
    Mounting Holes (2):.188 [4.75] Dia.
    30VK6/6C & 40VK6/6C


    Typical Dimensions:
    Terminals (5):8-32
    Torque 18 lbf-in. [2.03 N-m] max. ±2[.22]
    Mounting Slots (4):..250 x .156 [6.35 x 3.96] Dia.
    60VK6


    Typical Dimensions:
    Terminals (5):1/4-20,
    Torque 56 lbf-in. [6.32 N-m] max. ±2[.22]
    Mounting Slots (4):..250 x .156 [6.35 x 3.96] Dia.
    K7 & K7M (3, 5, 10A)

    Typical Dimensions:
    Load Terminals(2):.250 [6.3] with .07 [1.8] Dia. hole
    Ground Terminal(1):.250 [6.3] with .07 x .16 [1.8 x 3.8] slot
    Line Inlet (1):IEC 60320-1 C14
    K7 Inserts (2):6-32 x 1/4
    K7M Inserts (2):M3x.5
    20VK7


    Typical Dimensions:
    Load Terminals(2):.250 [6.3] with .07 [1.8] Dia. hole
    Ground Terminal(1):.250 [6.3] with .07 x .16 [1.8 x 3.8] slot
    Line Inlet (1):IEC 60320-1 C20
    K7 Inserts (2):6-32 x 1/4
    K7M Inserts (2):M3x.5
    Recommended Panel Cutouts

    K7 & K7M Cutout (3, 5, 10A)

    tolerance ± .005 [0.13]
    Back mount only
    20VK7


    tolerance ± .005 [0.13]
    Back mount only

    Available Part Numbers
    1VK110VK11EK110EK1
    1VK310VK31EK310EK3
    2VK110VK62EK110EK7
    2VK310VK72EK310EK7M
    3VK110VK7M3EK120EK1
    3VK320VK13EK3
    3VK720VK63EK7
    3VK7M20VK73EK7M
    5VK130VK65EK1
    5VK330VK6C5EK3
    5VK740VK65EK7
    5VK7M40VK6C5EK7M
    60VK6

    Corcom Catalog Part Number:
    1VK1
    TE Part Number:6609028-1
    1 Amp standard leakage K Series with 1/4 quick connect terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    1VK3
    TE Part Number:6609028-2
    1 Amp standard leakage K Series with wire lead terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    2VK1
    TE Part Number:6609028-3
    2 Amp standard leakage K Series with 1/4 quick connect terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    2VK3
    TE Part Number:6609028-4
    2 Amp standard leakage K Series with wire lead terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    3VK1
    TE Part Number:6609028-5
    3 Amp standard leakage K Series with 1/4 quick connect terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    3VK3
    TE Part Number:6609028-6
    3 Amp standard leakage K Series with wire lead terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    3VK7
    TE Part Number:6609028-7
    3 Amp standard leakage K Series with IEC input and 1/4 quick connect output terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    3VK7M
    TE Part Number:6609028-8
    3 Amp standard leakage K Series with IEC input and 1/4 quick connect terminals with metric tapped insert
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    5VK1
    TE Part Number:6609028-9
    5 Amp standard leakage K Series with 1/4 quick connect terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    5VK3
    TE Part Number:1-6609028-0
    5 Amp standard leakage K Series with wire lead terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    5VK7
    TE Part Number:1-6609028-1
    5 Amp standard leakage K Series with IEC input and 1/4 quick connect output terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    5VK7M
    TE Part Number:1-6609028-2
    5 Amp standard leakage K Series with IEC input and 1/4 quick connect terminals with metric tapped insert
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    10VK1
    TE Part Number:1-6609028-3
    10 Amp standard leakage K Series with 1/4 quick connect terminal
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    10VK3
    TE Part Number:1-6609028-4
    10 Amp standard leakage K Series with wire lead terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    10VK6
    TE Part Number:1-6609028-8
    10 Amp standard leakage K Series with stud terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    10VK7
    TE Part Number:1-6609028-5
    10 Amp standard leakage K Series with IEC input and 1/4 quick connect terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    10VK7M
    TE Part Number:1-6609028-6
    10 Amp standard leakage K Series with IEC input and 1/4 quick connect terminals with metric tapped insert
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    20VK1
    TE Part Number:1-6609028-7
    20 Amp standard leakage K Series with 1/4 quick connect terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    20VK6
    TE Part Number:1-6609028-9
    20 Amp standard leakage K Series with stud terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    20VK7
    TE Part Number:2-6609028-2
    20 Amp standard leakage K Series with IEC input and 1/4 quick connect output terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    30VK6
    TE Part Number:2-6609028-0
    3 0 Amp standard leakage K Series with stud terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    30VK6C
    TE Part Number:2-6609028-1
    3 0 Amp standard leakage K Series with stud terminals and ground choke terminal
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    40VK6
    TE Part Number:2-6609028-3
    EMF/RFI Filter(s)

    Corcom Catalog Part Number:
    40VK6C
    TE Part Number:2-6609028-4
    EMF/RFI Filter(s)

    Corcom Catalog Part Number:
    60VK6
    TE Part Number:2-6609028-5
    EMF/RFI Filter(s)

    Corcom Catalog Part Number:
    1EK1
    TE Part Number:6609027-1
    1 Amp low leakage K Series with 1/4 quick connect terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    1EK3
    TE Part Number:6609027-2
    1 Amp low leakage K Series with wire lead terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    2EK1
    TE Part Number:6609027-3
    2 Amp low leakage K Series with 1/4 quick connect terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    2EK3
    TE Part Number:6609027-4
    2 Amp low leakage K Series with wire lead terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    3EK1
    TE Part Number:6609027-5
    3 Amp low leakage K Series with 1/4 quick connect terminals
    UL Recognized / CSA Certified / VDE Approved

    Corcom Catalog Part Number:
    3EK3
    TE Part Number:6609027-6
    3 Amp low leakage K Series with wire lead terminals
    UL Recognized / CSA Certified / VDE Approved

Post Buying Request