product name:
General Purpose Relay
![](http://img.hisupplier.com/var/userImages/2012-09%2F21%2F171443250216.jpg)
•Ideally suited for high-inrush fluid pump controls: pool/spa, water
processing, emergency, chemical industry, etc.
• High-capacity, high-withstand voltage relay with no contact chattering
for momentary voltage drops up to 50% of rated voltage.
• UL Class B construction standard.
• Wide-range AC-activated coil that handles 100 to 120 VAC at either
50 or 60 Hz.
• Miniature hinge for maximum switching capacity, particularly for inductive
loads.
• Flame resistant materials (UL94V-0-qualifying) used for
all insulation material.
• Quick-connect, screw, and PCB terminals available.
• Standard models are UL, CSA, and TUV approved;
VDE/IEC 950 versions are now available. Meet pollution degree 3
Material Group II & III.
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., G7L-1A-T-CB-AC100/120).
![](http://img.hisupplier.com/var/userImages/2012-09%2F21%2F171641243288.gif)
Note: 1. E bracket or socket must be used for mounting (part number R99-07G5D). Refer to "Accessories" section for options and part numbers.
2. For VDE approved versions, please consult OMRON.
3. CE marking is provided only on non-PCB terminal versions.
![](http://img.hisupplier.com/var/userImages/2012-09%2F21%2F171822195455.gif)
1. Contact form
1A:SPST-NO
2A:DPST-NO
2.Terminal shape
T:Quick-connect terminals
P:PCB terminals
B:Screw terminals
3. Mounting construction
No symbol:E bracket type
UB:Upper bracket type
4.Special functions
No symbol:Without test button
J:With test button
5. 80: VDE approved version
(includes UL, CSA and TÜV)
6. CB: Class B insulation
7. Rated coil voltage
![](http://img.hisupplier.com/var/userImages/2012-09%2F21%2F172158030331.gif)
Note: A socket terminal cover is supplied with the P7LF-06 socket and does not attach directly to the G7L relays. It cannot be purchased separately.
![](http://img.hisupplier.com/var/userImages/2012-09%2F21%2F172239351114.gif)
Note: The P7LF-C terminal cover attaches directly to the G7L-B style relays. It is sold separately.
Specifications
![](http://img.hisupplier.com/var/userImages/2012-09%2F21%2F172326355880.gif)
Note: P level: λ60 = 0.1 x 10-6 operation.
![](http://img.hisupplier.com/var/userImages/2012-09%2F21%2F172403000168.gif)
![](http://img.hisupplier.com/var/userImages/2012-09%2F21%2F172425134389.gif)
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of +15%/-20% for AC rated current and ±15% for DC coil resistance.
2. Performance characteristic data are measured at a coil temperature of 23°C (73°F).
![](http://img.hisupplier.com/var/userImages/2012-09%2F21%2F172533043966.gif)
Note: Data shown are of initial value.
![](http://img.hisupplier.com/var/userImages/2012-09%2F21%2F172827362296.gif)