It's parameters:
Size: 320mm×1800mm×270mm
Weight: 3.0kg
Screen: 12.1inch colorful liquid TFT LCD
Resolution: 800×600
Security standard: IEC601-1, UL2601
Heartbeat rate of fetus:
The probe: the nine wafer, the wide beam, work like pulse, high sensitivity
The power of Ultrasonic wave : lower than 1 MW / cm2
The frequency of it's work: 1.0MHZ
How to handle the signal: Digital signal processing unit
Maximum audio power output: 1.5w
Contraction stress:
The range of measurement: 20~100 pressure unit
The Ultrasonic output of the probe:
According to the rule set in 1992, the negative peak of sound pressure should be less than 1MPa, the Acoustic beam and the sound intensity should be less than 20 MW/cm2, the instant average peak of the sound intensity should be less than 100 MW/cm2. The sound intensity of this monitor is less than 1MW/cm2.
The GEL:
Viscous water-based compound, no harm to the skin, no allergy, stable,and anti-bacteria.
ECG:
Gain option: four gears including ×1 \×2 \×4\×0.5
Calibration signal: 1mV
Common mode signal suppression: greater than 70dB
Accuracy of heartbeat: ±5 times/minute
Scan rate:12.5 mm / S,25 mm / S,50 mm / S three standard file
ST segment detection: range(-2.0mV----+2.0mV)
Bandwidth:0.5HZ~100HZ
Lead: total lead, I, II, III, avF, avR, avL, V1-V6
Using standard: Conform to the standard of ANSI/AMI EC13-1992
Responding time:1s
Way of alarming: both in sound and light
Heart rate alarm preset range:upper limit,1~255times/minute
Lower limit,0~254times/minute
NIBP:
Technic:display waveform
Working mode:manual or automatic
Measuring unit:Mm hg / Kpa
Security for overpressure:double way for secure
Deviation between each period:choose in 2\5\10\15\30\60minutes.
Time taking:less than 45s
Pressure range in cuff: 0 - 250 mmHg
Precision of blood pressure:according to the ANSI / AAMI SP10 made in 1992.
Original cuff inflation: 180 mmHg(new born 70mmHG,little child 120mmHg)
Cuff Subsequent inflation: original Systolic pressure + 30 mmHg
Range of blood pressure measurement:
Systolic pressure: 60 — 250 mmHg
Diastolic pressure: 40 — 220 mmHg
Average pressure:45 — 235 mmHg
Responding time:1s
Way of alarm;light and sound
Preset alarm limit:
Upper limit of Systolic pressure: 1 - 255 mmHg
Lower limit: 0 - 254 mmHg
Upper limit of Diastolic pressure: 1 -255 mmHg
Lower limit:0 -254 mmHg
SPO2 :
Range: 0~100%
Resolution: 1%
The times of pulse: 20~250times/minute
Precision: 70% — 100 % ±2%
Range of alarm:
Upper limit:1%~100%
Lower limit:0%~99%
TEMP:
Technic: High sensitive thermistor probe
It's range :20℃—45℃
Resolution: 0.1%
Precision:±0.1℃
Range of alarm:
Upper limit: 20.1℃ - 45.5℃
Lower limit: 20℃ - 45.4℃
RESP:
Breathing frequency: 0~60/minute
Precision: ±1bpm
Responding time:1s
Gain option: four gears including ×1 \×2 \×4\×0.5
Way of alarm:light and sound
Range of alarm:
Upper limit:10~100times/minute
Lower limit:0~99times/minute
Tendency diagram:
Type: table/form
Storage:48hours
The interval between data: 30seconds
Mode of form:all parameters have tendency
Mode of table: 11kinds of content in every line,15 lines on each page