user login

150kw Marine generator

Min. Order: 1 Set/Sets
Payment Terms: L/C, T/T
Supply Ability: 500 Set/Sets / Month
Place of Origin: Chongqing

Company Profile

Location: Chongqing, China (Mainland)
Business Type: Manufacturer, Trading Company, Distributor/Wholesaler
Main Products: Marine Power And Propulsion, Boats

Product Detail

Model No.: BMMPPMGY150
Means of Transport: Ocean, Air, Land
Output Type: AC Three Phase
Brand Name: Bochi
Speed: 1500r/min
Frequency: 50HZ
Rated Power: 80kw
Rated Voltage: 400
Rated Current: 271
Intake way: Turbo-cooled&inter-cooled
No. of Cylinder - bore*stroke: 6 - 120*145
Starting type: Electric start
Total displacement(L): 9.839
Min.fuel consumption g/(KW.h): ≤195
Oil capacity(L): 34
Lw Noise limit: ≤98
Regulator approach: AVR
Net Weight(kg): 2600
Packing size L*W*H(mm): 2500*960*1500
Production Capacity: 500 Set/Sets / Month
Packing: Wooden case
Delivery Date: about 30 days
Show

Product Description

Gensets Model
BMMPPMGY150
BMMPPMGY160
BMMPPMGY200
BMMPPMGY250
BMMPPMGY300
Rated Capacity(KVA)
150/188
160/200
200/250
313
300/375
EngineDiesel Model
YC6M240C
YC6M260C
YC6MK300C
YC6T400C
YC6T450C
Rated power/Speed(KW/r/min)
176/1500
192/1500
219/1500
294/1500
330/1500
Type
Vertical,inline,water-cooled,4 stroke
Intake way
Turbo-cooled&inter-cooled
No. of Cylinder - bore*stroke
6 - 120*145
6 - 145*165
Starting type
Electric start
Total displacement(L)
9.839
16.35
Min.fuel consumption g/(KW.h)
≤195
≤192
Oil capacity(L)
34
52
Lw Noise limit
≤98
GeneratorLan Generator Model
TZHW-150
TZHW-160
TZHW-200
TZHW-250
TZHW-300
Rated voltage
400
400
400
400
400
Current(A)
271
289
361
451
541
Regulator approach
AVR
Freq.(Hz)
50
Power factor(CosΦ)
0.8 lagging
Phase
3-phase
PackageNet Weight(kg)
2600
2600
2800
2500
3130
Packing size L*W*H(mm)
2500*960*1500
2800*1020*1700
The main technical indexes
1.characteristic of voltage regulation
ratio of steady state voltage regulation ≤±2.5%    ratio of transient state voltage regulation ≤±20-15%
steady time ≤1.5   ratio of voltage fluctuation ≤±1%   voltage setting range of non-load 95-105%rated current
2.performance of governoring
ratio of steady governoring   ≤5% ratio of transient governoring  ≤±10%
steady time ≤5S ratio of rotating speed fluctuation   ≤±0.5%
3.The generator set can overload 10% of the rated power for an hour after 12hours of rated power continuously .
4.Generator set can keep parallel running for a long time. The generator set can run steadily when the load changes at 20%-100% of rated power factor and can transform the load's active power and reactive power steadily. The active power's distribution degree can’t exceed 15% of the generator’s rated power, and the reactive power’s distribution degree can’t exceed 10% of the generator’s rated power.

Post Buying Request