user login

iec60502-1 600/1000V Mica XLPE Insulated, LSZH Sheathed Power Cables

100.0~100000.0 USD
Min. Order: 1000 Meter
Trade Term: FOB
Payment Terms: T/T
Supply Ability: 50000000

Company Profile

Location: Hong Kong
Business Type: Manufacturer
Main Products: U-1000 R2V Industrial Cables, Fire Resistant Power Cables, Mica Fireproof Control Cables, RS485 Data Bus Cables

Product Detail

Model No.: FFX400 1mRMZ1-R
Means of Transport: Ocean, Air, Land
Application: Power Station
Type: Low Voltage
Insulation Material: XLPE
Jacket: Others
Conductor Material: Copper
Brand Name: caledonian
Production Capacity: 50000000
Packing: wood box
Delivery Date: 30
Show

Product Description

600/1000V Mica+XLPE Insulated, LSZH Sheathed Power Cables (2-4 cores)
FFX400 1mRZ1-R (CU/MGT+XLPE/LSZH 600/1000V Class 2)
FFX400 1mRMZ1-R (CU/MGT+XLPE/LSZH/SWA/LSZH 600/1000V Class 2)
APPLICATION
This cable is designed for areas where the integrity of the electrical properties circuit is critical in maintaining power supply. Applications can be found in emergency lightings, control and power circuits, power stations, fire alarm systems, underground tunnels, communications systems, sewage treatment plants, lifts, escalators, and high-rise buildings.
STANDARDS
Basic design to IEC 60502-1/BS 7846
FIRE PERFORMANCE
Circuit Integrity
IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180);
CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3);
NF C32-070-2.3(CR1); BS 7846-(F2)
System circuit integrity
DIN 4102-12, E30 depending on lay system
Flame Retardance (Single Vertical Wire Test)
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2;
VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2);
CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4
Halogen Free
IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1;
CEI 20-37/2-1 ; BS 6425-1*
No Corrosive Gas Emission
IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2;
CEI 20-37/2-2 ; BS 6425-2*
Minimum Smoke Emission
IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2;
CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*
No Toxic gases
NES 02-713; NF C 20-454
Note: Asterisk * denotes superseded standard.
VOLTAGE RATING
600/1000V
CABLE CONSTRUCTION
Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.
Insulation: Mica glass tape covered by extruded cross-linked XLPE compound
Cabling: The cores are cabled together in concentric layers with suitable non-hygroscopic fillers.
Inner Sheath(optional): Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 Armouring(optional): Galvanized steel wire armour
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)
COLOUR CODE
Insulation Colour
2 - Core: (Brown & Blue)
3 - Core: (Brown, Black & Grey)
4 - Core: (Brown, Black, Grey & Blue)
Sheath Colour
Orange (other colors upon request)
Physical AND THERMAL PROPERTIES
Temperature range during operation (fixed state): -30°C – +90°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 8 x Overall Diameter (unarmoured cable)
10 x Overall Diameter (armoured cable)
Electrical PROPERTIES
Dielectric test:
3500 V r.m.s. x 5' (core/core)
Insulation resistance
1000 MΩ x km (at 20°C)
Short circuit temperature
250°C
CONSTRUCTION PARAMETERS
Conductor
FFX400 1mRZ1-R
FFX400 1mRMZ1-R
Unarmoured Cable
Armoured Cable
Nominal Area
No./Nominal Diameter of Strands
Dia. of Conductor
Nominal Insulation Thickness
Nominal Overall Diameter
Approx. Weight
Nominal Overall Diameter
Approx. Weight
mm2
No./mm
mm
mm
mm
kg/km
mm
kg/km
2-CORE
1.5
7/0.53
1.59
0.7
12.2
150
15.3
390
2.5
7/0.67
2.01
0.7
12.6
180
16.5
450
4
7/0.85
2.55
0.7
14.7
250
17.6
525
6
7/1.04
3.12
0.7
16.2
290
18.8
620
10
7/1.35
4.05
0.7
17.1
450
21
800
16
7/1.70
5.1
0.7
19.2
550
23
1100
25
7/2.14
6.42
0.9
20
680
27
1480
35
19/1.53
7.65
0.9
22
940
30
2000
50
19/1.78
8.9
1
24
1250
33
2450
70
19/2.14
10.7
1.1
27
1700
37
3200
95
19/2.52
12.6
1.1
31
2300
42
4350
120
37/2.03
14.21
1.2
36
3150
48
6500
3-CORE
1.5
7/0.53
1.59
0.7
12.3
170
16.5
420
2.5
7/0.67
2.01
0.7
13.8
200
17
500
4
7/0.85
2.55
0.7
15.2
300
18.5
600
6
7/1.04
3.12
0.7
16.8
380
19.8
785
10
7/1.35
4.05
0.7
18
550
22.6
1030
16
1/1.70
5.1
0.7
21
760
25
1370
25
7/2.14
6.42
0.9
22
960
29
1900
35
19/1.53
7.65
0.9
24
1300
32
2300
50
19/1.78
8.9
1
28
1700
35
2900
70
19/2.14
10.7
1.1
31
2400
40
4000
95
19/2.52
12.6
1.1
36
3250
45
5400
120
37/2.03
14.21
1.2
38
4000
49
6450
150
37/2.25
15.75
1.4
42
5000
55
8200
185
37/2.52
17.64
1.6
47
6100
60
9800
240
61/2.25
20.25
1.7
52
8000
68
12300
300
61/2.52
22.68
1.8
59
9850
74
14800
400
61/2.85
25.65
2
63
13000
83
17600
4-CORE
1.5
7/0.53
1.59
0.7
14.3
210
16
475
2.5
7/0.67
2.01
0.7
15.2
270
17.8
570
4
7/0.85
2.55
0.7
17.2
380
19.8
690
6
7/1.04
3.12
0.7
19
440
21
940
10
7/1.35
4.05
0.7
20.6
670
23.3
1200
16
1/1.70
5.1
0.7
23.6
820
26.5
1400
25
7/2.14
6.42
0.9
26
1320
30.5
2400
35
19/1.53
7.65
0.9
29
1730
34
2800
50
19/1.78
8.9
1
32
2300
38
3500
70
19/2.14
10.7
1.1
38
3180
44
5300
95
19/2.52
12.6
1.1
41.9
4370
48.5
6700
120
37/2.03
14.21
1.2
44
5400
54
8500
150
37/2.25
15.75
1.4
50.8
6500
59
10000
185
37/2.52
17.64
1.6
55
8200
64.5
12200
240
61/2.25
20.25
1.7
60.5
10600
74
15400
300
61/2.52
22.68
1.8
68.5
13200
82
19500
400
61/2.85
25.65
2
76
17000
92
25500
ElectricAl PROPERTIES
Conductor Operating Temperature : 90°C
Ambient Temperature : 30°C
FFX400 1mRZ1-R
Current-Carrying Capacities (Amp)
Nominal Cross
Section
Area
Reference Method 4 (enclosed in an conduit insulated wall etc)
Reference Method 3
Reference Method 1 (clipped direct)
Reference Method 11
(enclosed in conduit on a wall or ceiling, or in trunking)
(on a perforated cable tray), or Reference Method 13 (free air)
one 3-core cable or one 4-core cable 3-phase a.c.
one 2-core cable single
phase a.c. or d.c.
one 3-core cable or one 4-core cable 3-phase a.c.
one 2-core cable single
phase a.c. or d.c.
one 3-core cable or one 4-core cable 3-phase a.c.
one 2-core
one 3-core
cable singlephase
cable or one
a.c. or
4-core cable
d.c.
3-phase a.c.
1
2
3
4
5
6
7
8
mm2
A
A
A
A
A
A
A
1.5
16.5
22
19.5
24
22
26
23
2.5
22
30
26
33
30
36
32
4
30
40
35
45
40
49
42
6
38
51
44
58
52
63
54
10
51
69
60
80
71
86
75
16
68
91
80
107
96
115
100
25
89
119
105
138
119
149
127
35
109
146
128
171
147
185
158
50
130
175
154
209
179
225
192
70
164
221
194
269
229
289
246
95
197
265
233
328
278
352
298
120
227
305
268
382
322
410
346
150
259
334
300
441
371
473
399
185
295
384
340
506
424
542
456
240
346
459
398
599
500
641
538
300
396
532
455
693
576
741
621
400
-
625
536
803
667
865
741
Voltage Drop (Per Amp Per Meter)
Nominal Cross
Section Area
2-core cable d.c.
2-core cable single-phase a.c
3-core or 4-core cable 3-phase a.c.
1
2
3
4
mm2
mV/A/m
mV/A/m
mV/A/m
1.5
31
31
27
2.5
19
19
16
4
12
12
10
6
7.9
7.9
6.8
10
4.7
4.7
4
16
2.9
2.9
2.5
r
x
z
r
x
z
25
1.85
1.85
0.16
1.9
1.6
0.14
1.65
35
1.35
1.35
0.155
1.35
1.15
0.135
1.15
50
0.98
0.99
0.155
1
0.86
0.135
0.87
70
0.67
0.67
0.15
0.69
0.59
0.13
0.6
95
0.49
0.5
0.15
0.52
0.43
0.13
0.45
120
0.39
0.4
0.145
0.42
0.34
0.13
0.37
150
0.31
0.32
0.145
0.35
0.28
0.125
0.3
185
0.25
0.26
0.145
0.29
0.22
0.125
0.26
240
0.195
0.2
0.14
0.24
0.175
0.125
0.21
300
0.155
0.16
0.14
0.21
0.14
0.12
0.185
400
0.12
0.13
0.14
0.19
0.115
0.12
0.165
FFX400 1mRMZ1-R
Current-Carrying Capacities (Amp)
Nominal Cross
Section Area
Reference Method 1 (clipped
direct)
Reference Method 11 (on a perforated horizontal cable tray or Reference Method 13 [free
air] )
In single-way ducts
Laid direct in ground
one 2-core cable single phase a.c. or d.c.
one 3-core or 4-core cable 3-phase a.c.
one 2-core cable single phase a.c. or d.c.
one 3-core or 4-core cable 3-phase a.c.
one 2-core cable single phase a.c. or d.c.
one 3-core or 4-core cable 3-phase a.c.
one 2-core cable single phase a.c. or d.c.
one 3-core or 4-core cable 3-phase a.c.
1
2
3
4
5
6
7
8
9
mm2
A
A
A
A
A
A
A
A
1.5
27
23
29
25
-
23
-
28
2.5
36
31
39
33
-
30
-
36
4
49
42
52
44
-
40
-
48
6
62
53
66
56
-
50
-
60
10
85
73
90
78
-
65
-
80
16
110
94
115
99
115
94
140
115
25
146
124
152
131
145
125
180
150
35
180
154
188
162
175
150
215
180
50
219
187
228
197
210
175
255
215
70
279
238
291
251
260
215
315
265
95
338
289
354
304
310
260
380
315
120
392
335
410
353
355
300
430
360
150
451
386
472
406
400
335
480
405
185
515
441
539
463
455
380
540
460
240
607
520
636
546
520
440
630
530
300
698
599
732
628
590
495
700
590
400
787
673
847
728
660
560
790
670
Voltage Drop (Per Amp Per Meter)
Nominal Cross
Section Area
2-core cable d.c.
2 cables, single-phase a.c.
3 or 4 cables, 3-phase a.c.
2 cables,
single-phase
a.c.
3 or 4 cables,
3-phase a.c.
In ducts or
in ground
In ducts or
in ground
1
2
3
4
5
6
mm2
mV/A/m
mV/A/m
mV/A/m
mV/A/m
mV/A/m
1.5
31
31
27
31
25
2.5
19
19
16
19
15
4
12
12
10
12
9.7
6
7.9
7.9
6.8
7.9
6.5
10
4.7
4.7
4
4.7
3.9
16
2.9
2.9
2.5
2.9
2.6
r
x
z
r
x
z
25
1.85
1.35
0.16
1.9
1.6
0.14
1.65
1.9
1.6
35
1.35
1.35
0.155
1.35
1.15
0.135
1.15
1.35
1.2
50
0.98
0.99
0.155
1
0.86
0.135
0.87
1
0.87
70
0.67
0.67
0.15
0.69
0.59
0.13
0.6
0.69
0.61
95
0.49
0.5
0.15
0.52
0.43
0.13
0.45
0.52
0.45
120
0.39
0.4
0.145
0.42
0.34
0.13
0.37
0.42
0.36
150
0.31
0.32
0.145
0.35
0.28
0.125
0.3
0.35
0.3
185
0.25
0.26
0.145
0.29
0.22
0.125
0.26
0.29
0.25
240
0.195
0.2
0.14
0.24
0.175
0.125
0.21
0.24
0.21
300
0.155
0.16
0.14
0.21
0.14
0.12
0.185
0.21
0.19
400
0.12
0.13
0.14
0.19
0.115
0.12
0.165
0.19
0.18
Note : r = conductor resistance at operating temperature