user login

Low-voltage switch gear

Min. Order: 1 PCS
Payment Terms: L/C

Company Profile

Location: Zhengzhou, Henan, China (Mainland)
Business Type: Manufacturer, Trading Company
Main Products: Pipe Mould, Ductile Iron Pipe Fitting

Product Detail

Means of Transport: Ocean

Product Description

Outlined
Type GCS low-voltage withdrawable switchgear (hereinafter referred to as the "device) is two joint design according to the competent trade authorities, and the general electric power users and design the requirement of the unit design developed with the situation of China, with high technology performance index, can adapt to the development needs of the power market and can introduce products with existing competitive low-voltage withdrawable switchgear. This device in July 1996 in Shanghai two jointly hosted by the appraisal. Manufacturing unit and power by using departments pay and sure.
Characterstics
Low-voltage switchgear
1 piece improve the heat transfer capacity, reduced significantly the temperature rise due to transfer pieces of connectors, cable ends, the added plate temperature interval (2) between the functional units, a clear separation between compartments, reliable, not because of the failure of a unit affected by the work of other units, the fault confined to the minimum. 3 Flat-mounted bus dynamic, thermal stability, can withstand the impact of short-circuit current 80/176KA. 4. MCC cabinet single cabinet to 22 the maximum number of loop back, take full account of the large stand-alone capacity power plants, petrochemical and other industries automatic electric door system (machine) group needs. 5 devices and external cables to complete the cable compartment, the cable can be up and down and out.
Application
Device used in power plant, petroleum, chemical industry, metallurgy, textile, high-rise building etc of the power distribution system. In large power plant, petrochemical system a high degree of automation, requirements and computer interface of places
Working conditons
Low-voltage switchgear
1. The air temperature is not higher than around + 40 ℃, not less than 5 ℃. 24 hours may not be higher than the average temperature + 35 ℃ 2. Indoor use, use the altitude of the site shall not be more than 2000 m. 3. The ambient air relative humidity in the highest temperature + 40 ℃ not more than 50% 4. Device with the slope of the perpendicular installation of no more than 5% of the ark, and the relative level off (GJB232 listed with 82 standard). 5. Device installed in no violent vibration and impact and not enough to make the electrical components are not due corrosion of places.
Post Buying Request