Place of Origin: | Guangdong |
---|
Location: | China (Mainland) |
---|---|
Business Type: | Manufacturer |
Use: | Bathroom |
---|
Model No. Parameter | Unit | FC-KF76 | FC-KF110 | FC-KF150 |
Heat Capacity | KW | 3.8 | 5 | 7 |
BTU/h | 12900 | 17000 | 24000 | |
COP | — | 4.5 | 4.5 | 4.5 |
Max Water Outlet Temperature | ℃ | Default 55 ℃,adjustable between 30 ℃~60 ℃ | ||
Power Supply | V/PH/Hz | 220V/50Hz | ||
Rated Input Power (Heating/Cooling) | KW | 0.7 | 1.2 | 1.72 |
Rated Input Current (Heating/Cooling) | A | 3.1 | 5.6 | 7.8 |
Max Input Power | KW | 0.9 | 1.5 | 2.32 |
Max Input Current | A | 4.3 | 7.0 | 11.0 |
Ambient Temperature | ℃ | -7~43 | ||
Heat Exchanger | — | Fin and stainless steel tank | ||
Refrigerant/Volume | Kg | R407C/0.9 | R407C/1.2 | R407C/1.5 |
Compressor Type and Quantity | — | Panasonic/1 | Panasonic/1 | Panasonic/1 |
Fan Quantity | pcs | 1 | 1 | 1 |
Fan Air Flow Volume | m3h | 2300 | 2600 | 3000 |
Fan Direction | — | Side Blown | ||
Fan Power Input | W | 25 | 25 | 25 |
Fan Rotation Speed | RPM | 960 | 960 | 960 |
Noise | dB (A) | 45 | 50 | 50 |
Pipe Diameter | mm | DN15 | DN15 | DN20 |
Discharge Pressure | Mpa | 2.5 | ||
Suction Pressure | Mpa | 0.3~0.8 | ||
Rated Water Pressure | Mpa | 0.2~0.6 | ||
Max Water-in Pressure | Mpa | 0.7 | ||
Min Water-in Pressure | Mpa | 0.15 | ||
Hot Water Volume | L/h | 76 | 110 | 150 |
Net Weight | Kg | 23 | 35 | 38 |
Shipping Weight | Kg | 24 | 37 | 40 |
Product Dimension | mm | 600*235*500 | 770*250*540 | 770*250*540 |
Shipping Size | mm | 764*344*554 | 915*343*600 | 915*343*600 |