user login

Pulse Oximeter

Min. Order: 1 Set/Sets
Trade Term: FOB
Payment Terms: T/T, WU
Supply Ability: 50 Unit
Place of Origin: Shanghai

Company Profile

Location: China (Mainland)
Business Type: Manufacturer, Agent, Distributor/Wholesaler

Product Detail

Model No.: MM-POS50QA
Means of Transport: Ocean, Air, Land
Brand Name: Moonlit
Production Capacity: 50 Unit
Packing: Standard Packing
Delivery Date: 15 working days
Show

Product Description

Instructions

Principle of the MM-POS50QA Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology,the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger.The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc
Major Features
. Integrated with SpO2 probe and processing display module
. Small in volume\light in weight and convenient in carrying
. Operation of the product is simple ,low power consumption
. SpO2 value display
. Pulse rate value display, bar graph display
. A pulse rate sound indication
. With measured data overruns limits and low-voltage alarm function
. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage,and with alarm function
. Automatically power off function: when the device is under the state of measuring interface .
   it will automatically power off within 5 seconds if the finger falls out of probe.
. Small appearance,more fit for children
Main performance
Display Mode: Segment LCD display
SpO2 Measuring Range:0%~100%, (the resolution is 1%).
Accuracy:70%~100%:±2% ,Below 70% unspecified.
PR Measuring Range:30bpm~250bpm, (the resolution is 1bpm)
Accuracy:±2bpm or ±2% (select larger)
Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%.
SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light
and that of darkroom is less than ±1%.
Power Consumption:less than 50mA
Voltage:DC 3.6V~4.2V
Power Supply:Voltage 3.6 rechargeable lithium battery × 1
Battery working hour:10 hours
Battery working life:Charge and discharge no less than 300 times.
Safety Type:Interior Battery,BF Type
Accessories
Sell in standard
. a hanging rope
. a user manual
. One rechargeable buttony lithium battery
. Charge accessories: One power adapter, one charger, one data line
Physical Identity
Dimension:46(L) × 40(W) × 29(H) mm
Weight:About 35g (with a buttony lithium battery)
Post Buying Request