user login

Limb function rehabilitation evaluation and training system

Min. Order: 1 Set/Sets
Trade Term: FOB
Payment Terms: T/T, WU
Supply Ability: 50 Unit
Place of Origin: Shanghai

Company Profile

Location: China (Mainland)
Business Type: Manufacturer, Agent, Distributor/Wholesaler

Product Detail

Model No.: : MM-Reh01
Means of Transport: Ocean, Air, Land
Brand Name: Moonlit
Production Capacity: 50 Unit
Packing: Standard Packing
Delivery Date: 15 working days
Show

Product Description

Function:          
.  This system include Multi-Model electrical stimulation,EMG, grip, evaluation and training of
muscle strength,and goniometer modules.Those modules functions are throughout the early period
to later period of rehabilitation.
.  Multi-Model electrical stimulation can increase muscular endurance, slow muscle atrophy,
increase muscle strength, decrease muscle spasm and relieve pain. Also can make diagnostic
and training for grip,pinch force, Finger force,muscle strength and ROM.
Increase Multi-media training model in every module for funny,
improve active participation of patients.
Features and advantages:
.  Portable design, powerful function; It include evaluation & training of
      Multi-Model electronic stimulation ,EMG, grip, muscle strength and ROM.
.  Work with Surface EMG, evaluate special muscle function ofthe upper motor neuron syndrome ; 
      Reflect influence of antagonistic muscle over-activity against agonist muscle.
.  Grip module acquisit grip signal from patients, and makethresholdelectronic stimulation
      or Multi-media training.
.  Muscle strength Module have wide application, like examination of weak muscle strength.
.  Each module has Multi-media training mode, it can increase interesting
      and positiveness during training.
Clinical application:
.  Enhance muscle tension, preventmuscular dystrophy and decreasemuscle spasm during early treatment.
.  Trainrelaxation ability, endurance ability, controlling ability ,accuracy of patient's muscle .
.  Precision evaluation for treatment progress of patient's hand, and improve patient's grip.
Application for Hospital department:
. Neurology department-- Cerebral apoplexy, traumatic brain injury, brachial plexus.
.  Orthopedics department--- illness ofbone ,joint and muscle: Inflammation and injury of bone and joint.
      Injure of peripheral nerve,muscle spasm , muscular atrophy and ligament injury.
.  Pain center—Muscle painful, like Neck, shoulder, waist, leg and so on.
Technical parameter:
.  Measurement range: 1μV~2000μV
.  Maximum resolution: ≤0.2μV
. Input noise: <1μV
.  Passband:10Hz~1000Hz
.  Differential input impedance:≥20MΩ
.  CMRR: ≥110 dB
.  Current stimulation intensity: 0~100mA,resolution 1mA, error≤±10%
.  Pulse-width of Current stimulation: 50μs~500μ,error≤±10%
.  Current stimulation frequency: 1HZ~160HZ, error≤±5%
.  Measurement range of grip sensor: 0~1000N
.  Measurement range ofdynamometer: 0~500N
Post Buying Request