High performance 12kv high voltage outdoor vacuum circuit breaker

Min. Order: 1 Piece/Pieces
Trade Term: FOB
Payment Terms: L/C, D/P, D/A, T/T, WU
Supply Ability: 20000/year
Place of Origin: Hubei

Company Profile

Location: China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: ZW10-12
Means of Transport: Ocean, Air, Land
Certification: ISO9001
Production Capacity: 20000/year
Packing: cartons
Delivery Date: as you request
Show

Product Description

High quality ZW10-12 outdoor high voltage vacuum circuit breaker
1.vacuum circuit breaker
2. IEC standard
3.Reliable Long service life,
4.Short delivery time
5.high quality ,low price1
Ambient temperature:
max +40°C min -15°C(conveyance under -30°C is allowed)
2 Altitude: ≤1000m
3 Relative humidity: daily average relative humidity: ≤95%; monthly average relative humidity≤90%; daily average saturated vapor pressure ≤2.2*10-3 MPa; monthly average value  ≤1.8*10-3 MPa
4 Earthquake intensity: ≤8 degree
5 The installation should be free from fire, explosion, severe vibration, chemical corrosion and serious pollution
Order instruction
Complete model and order quantity of the product
Rated current, rated voltage, distance of each poles
Rated short circuit breaking current, operation voltage
Required accessory and quantity
Other requirement please contact with us directly
Main Technical Data
Rated voltage                                                           kv12
Rated frequency                                                         Hz50
Rated lighting impulse withstand voltagekv
Interphase or to ground 75,
fructure 80
Rated short-time power frequency withstand voltage    kv
Interphase or to ground 42,
fructure 48
Rated current                                                             A63010001250
Rated short-circuit breaking current                              kA12.51620
Rated short-circuit making current                               kA31.54050
Rated short-time withstand current                         kA12.51620
Rated peak withstand current                               kA31.54050
Rated operations of short-circuit breaking current interruption   times30
Rated operating sequence                                             0-0.3-CO-180s -CO
Mechanical life                                           times10000
Contact erosion limit                                       m3
Rated operating voltage of opening and closing coil(CT23 spring operating structure)                                          v       AC,DC220             
Rated working current of overcurrent and tripping coilA5
Current transformer current ratio of two times(normal)
200/5,400/5,630/5,
1000/5,1250/5
Rated voltage of energy saving motorvAC,DC220       
Power of energy saving motorw≤70
Weightkg150
Note:Rated characteristics can be given on requirment