user login

12V/24V Battery Auto Sensing Charge Controller

Min. Order: 100 Piece/Pieces
Payment Terms: L/C, D/P, D/A, T/T, WU
Supply Ability: 1000 Piece/Pieces per Month
Place of Origin: Zhejiang

Company Profile

Location: Ningbo, Zhejiang, China (Mainland)
Business Type: Manufacturer, Trading Company
Main Products: Solar Power System, Solar System Control Boxes, Solar Charge Controllers, Wind Charge Controller, Wind Power Inverter

Product Detail

Model No.: DF-SUN SC30B
Means of Transport: Ocean
Production Capacity: 1000 Piece/Pieces per Month
Packing: standard export packing
Delivery Date: 20 days after advance payment
Show

Product Description

12V/24V Battery Auto Sensing Charge Controller

Picture 1

Specification
DF-SUN SC30B1224 ( 12V/24V Battery Auto Sensing)
Rated Cable Charging Current
30A
Rated Load Current
30A
System Voltage
12V
24V
Overload, Short Circuit Protection
YES
No load current
≤20 mA
Charging Circuit Voltage Drop
Not more than 0.26V
Discharging Circuit Voltage Drop
Not more than 0.15V
DC Charge Voltage
14.4V
28.8V
Float Charging
13.7V
27.4V
Temperature Compensation
-5mv/℃/2V
Automatic Disconnection
Output Voltage
10.5V
21V
Control Method
Charge for the PWM pulse width modulation, the control point voltage for different discharge rates of intelligent compensation amendment;

















Mechanics
Size: 165mm*102mm*40mm
G.W.: 0.4Kg
Environmental conditions
Operating temperature -20°C to 40°C
Storage temperature -20°C to 50°C

Picture 2

Picture 3

The controller has 1 LCD displayer, 1 button, and 6 terminals covered with the cover, see the picture 1.
The LCD has two-row, it will display the voltage of battery, the charging state, the DC output ON/OFF state, timer information and light control & delay time information, see picture 2 and picture 3.

There are 4 areas on the panel of LCD. Left-up displays the voltage of battery. Left-down is a bar, when the sun is shining, and the solar panel is charging the battery, the bar will rotate from left to right, and the length will be from short to long; when there is no sunshine, the bar will not rotate, just display the state of the battery, if the battery is full, the bar is long, and if the battery is empty, then the bar is short. Right-up displays the regular time or the light control state. Right-down display the DC output state, if the DC output is on, then it will display "Load: Y", if the DC output is off, then it will display "Load: N", if the load is too big, an overload is caused, it will display "Load: O", and if the load is short circuit, the it will display "Load: S".

Application
Connecting the solar panel to the solar panel terminals of the charger, "+" to “+” and “-“ to “-“.
Connecting the battery to the battery terminals of the charger, “+” to “+” and “-“ to “-“.
Connecting the DC load to the load terminals of the charge, take care of the “+” and “-“ of the DC output.
If the controller isn't at the setup state, regular time state, or light control and delay time state, press the power button, will control the DC output ON or Off.
Pressing the power button for about 2 seconds, the right-up area will show “Time :00”, and the figures will flash, then you release this button immediately, it indicates that the controller enters the timer setup state, at this state, every press of the power button will make the figures change from “00” to “15”, the figures indicate the power on time of the DC output , for example, if you change the digital as “03”, then the charge will switch on the DC output and will auto switch off the DC output in 3 hours, If the figures are “00”, it means that the regular timer is invalid. When you don't press the button for about 4 seconds, then the controller will quit the setup state automatically.
Pressing the power button for about 4 second, the right-up area will show “L+D :00”, and the figures are flashing, then you release this button, it indicates that the charger enters the light control and delay time setup state, at this state, every press of the power button will make the digital change from “00” to “15”, figures indicate the delay time of the load, for example, if you change the digital as “03”, then the charge will switch on the DC output when the night is coming and it will auto switch off the DC output in 3 hours. When you don't press the button for about 4 seconds, then the controller will quit the setup state automatically. When you set it as “L+D :00”, then it means the controller is at light control and no delay time state, it will switch on the DC output when the night is coming, and will switch off the DC output when the day time is coming. When the controller is at the light control state or light control and delay time state, you can't switch on the DC output by the button in day time, but you can switch off the DC output at night. If you don't want the light control function, just set the controller to “Time :00” state. When the voltage of the battery is too low, the controller will automatically switch off the DC output, in order to protect the battery to be over-discharged.

Solar Charge Controller User Manual
PWM Control Charger
Adjustable Loading Timer
Adjustable Light On + Delay Off Timer
12V and 24V Battery Auto sensing

Preface
Solar Charge Controller is battery charger that can charge batteries by the power from the solar panels. The charge controller is intelligent for charging batteries, using MCU and professional software to control the step of charging, can prolong the batteries’ life.
It has full self protection, protection of overload, short circuit, reverse connection, over charging and over discharging etc.
This model controller is 12V/24 Battery Auto-Sensing.
When the Battery is connected to the Charge controller, the controller will detect the voltage of the battery first, then it will decide how to charge the battery connected.
Post Buying Request