The HT2400 product line, which includes HT2420, HT2432, HT2436, HT2464 and HT24120, is a programmable DC power supply family that features high accuracy, high stability and low noise with single channel output.
With the embedded16-Bit digital to analog converter, which controls output voltage/current, and 24-Bit analog to digital converter, which reads output voltage/ current and high accuracy voltage reference resources, users attain precise input and output figures.
In terms of over voltage/current protection (OVP/OCP), the HT2400 rapidly detects a problem by utilizing a combination of software configuration and hardware detection, which ensures connected objects against damages if any problem occurs.
Features:
1. Stable output regulation with low noise and high precision
2. High resolution of output capabilities: Voltage= 1 mV. Current= 100uA.
3. High resolution of read-back capabilities: Voltage= 1 mV Current= 1uA
4. Remote Sense compensation
5. Front panel and rear panel output terminals
6. Back lighted 20x2 LCD display
7. Over-voltage and over-current protection
8. Short circuit and reverse polarity Protection
9. Intelligent Fan control
10. Auto Run mode and delay time setting functions
11. Ramp output function
12. 100 configurable and recallable states in the memory
13. ON/OFF control at the output terminal
14. Standard RS-232C and USB interfaces Optional GPIB(IEEE-488.2) interface
Model HT2420 HT2432 HT2436 HT2464 HT24120Output
Voltage 0 ~ 20V 0 ~ 32V 0 ~ 36V 0 ~ 64V 0 ~ 120V
Current 0 ~ 5A 0 ~ 3A 0 ~ 3A 0 ~ 1.5A 0 ~ 0.75A
OVP 0.1 ~ 21V 0.1 ~ 34V 0.1 ~ 38V 0.1 ~ 66V 0.1 ~ 130V
OCP 0.01 ~ 5.2A0.01 ~ 3.2A 0.01 ~ 3.2A 0.01 ~ 1.7A0.01 ~ 0.8A
Load Effect
Voltage <0.01 percent+ 2mV
Current <0.06 percent+ 2mA
Source Effect
Voltage <3mV
Current <3mA
Ripple and noise
Voltage <1mVrms
Current <3mArms (<5mArms when Load>3A)
Programming accuracy
Voltage <0.02 percent+ 5mV
Current <0.05 percent+ 8mA
OVP <0.05 percent+ 20mV
OCP <0.1 percent+ 5mA( +10mA when Load>3A)
Programming Resolution
Voltage 1mV 1mV 1mV 1mV 10mV
Current 100uA 100uA 100uA 100uA 100uA
OVP 10mV 10mV 10mV 10mV 100mV
OCP 1mA 1mA 1mA 1mA 1mA
Read-back accuracy
Voltage <0.02 percent+ 5mV
Current <0.02 percent+ 5mA, <0.1 percent+ 15uA (of 50mA range)
Read-back resolution
Voltage 1mV 1mV 1mV 1mV 10mV
Current 100uA, 1uA(of 50mA range)
Transient Response Time <50us (50 percent to 100 percent load effect)
OVP/OCP accuracy
Voltage <0.05 percent+ 20mV
Current <0.1 percent+ 5mA (+10mA when Load>3A)
Stability (8hrs) Voltage <0.02 percent+ 1mV