Min. Order: | 200 Piece/Pieces |
---|---|
Trade Term: | FOB |
Payment Terms: | L/C, T/T, WU |
Supply Ability: | 50000 Pieces / Month |
Place of Origin: | Zhejiang |
Location: | Wenzhou, Zhejiang, China (Mainland) |
---|---|
Business Type: | Manufacturer, Trading Company |
Model No.: | PS-65 |
---|---|
Means of Transport: | by air or by sea |
Input Voltage: | 220V |
Output Type: | Single |
Output Power: | 51 - 100W |
Brand Name: | INTMW |
Output Voltage: | 3.3V, 5V, 7.5V, 12V, 13.5V, 15V, 24V, 27V, 48V |
Output Frequency: | N/A |
Output Current: | 12A, 12A, 8A, 5.2A, 4.7A, 4.2A, 2.7A, 2.4A, 1.35A |
Dimension: | 127*76*42mm (L*W*H) |
Certificate: | CE, RoHS |
Safety Compliance: | EMC & LVD |
Weight: | 0.21Kg |
Production Capacity: | 50000 Pieces / Month |
Packing: | 0.21Kg; 54pcs/14.2Kg/1.35CUFT |
Delivery Date: | 7 ~ 15Day |
MODEL | PS-65-3.3 | PS-65-5 | PS-65-7.5 | PS-65-12 | PS-65-13.5 | PS-65-15 | PS-65-24 | PS-65-27 | PS-65-48 | |
OUTPUT | DC VOLTAGE | 3.3V | 5V | 7.5V | 12V | 13.5V | 15V | 24V | 27V | 48V |
RATED CURRENT | 12A | 12A | 8A | 5.2A | 4.7A | 4.2A | 2.7A | 2.4A | 1.35A | |
CURRENT RANGE | 0 ~ 15.2A | 0 ~ 13.8A | 0 ~9.6A | 0 ~ 6A | 0 ~ 5.4A | 0 ~ 4.8A | 0 ~ 3A | 0 ~ 2.7A | 0 ~ 1.5A | |
RATED POWER | 39.6W | 60W | 60W | 62.4W | 63.5W | 63W | 64.8W | 64.8W | 64.8W | |
OUTPUT POWER (max.) | Rated output power for convection; 72W (+3.3V: 50W;+5V: 69W) with 18 CFM min. Forced air | |||||||||
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |
VOLTAGE ADJ. RANGE | 3.14 ~ 3.63V | 4.75 ~ 5.5V | 7.13 ~ 8.25V | 11.4 ~ 13.2V | 12.8 ~ 14.9V | 14.25 ~ 16.5V | 22.8 ~ 26.4V | 25.65 ~ 29.7V | 45.6 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±3.0% | ±3.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±3.0% | ±3.0% | ±3.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | |
SETUP, RISE, HOLD TIME | 800ms, 20ms, 60ms at full load | |||||||||
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | ||||||||
FREQUENCY RANGE | 47 ~440Hz | |||||||||
EFFICIENCY (Typ.) | 69% | 76% | 79% | 79% | 79% | 79% | 80% | 80% | 80% | |
AC CURRENT | 1.2A/115VAC 0.72A/230VAC | |||||||||
INRUSH CURRENT (max.) | COLD START 20A/115VAC 40A/230VAC | |||||||||
LEAKAGE CURRENT | <0.5mA/240VAC | |||||||||
PROTECTION | OVERLOAD | 73 ~ 105W (3.3V: 51 ~ 75 W) (5V: 70 ~ 105) rated output power | ||||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed. | ||||||||||
OVER VOLTAGE | 3.8 ~ 4.46V | 5.75 ~ 6.75V | 8.63 ~ 10.1V | 13.8 ~ 16.2V | 15.5 ~ 18.2V | 17.25 ~ 20.25V | 27.6 ~ 32.4V | 31 ~ 36.45V | 55.2 ~ 64.8V | |
Protection type: Hiccup mode, recovers automatically after fault condition is removed. | ||||||||||
ENVIRONMENT | WORKING TEMP. | -10 ~ +60ºC | ||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -20 ~ +85ºC, 10 ~ 95% RH | |||||||||
TEMP. COEFFICIENT | ±0.04%/ºC (0 ~ 50ºC) | |||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||||
SAFETY & EMC(Note4) | SAFETY STANDARDS | Design refer to UL60950-1,TUV EN60950-1 | ||||||||
WITHSTAND VOLTAGE | I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | |||||||||
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B | |||||||||
HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | |||||||||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A | |||||||||
OTHERS | MTBF | 300.7Khrs min. MIL-HDBK-217F(25ºC) | ||||||||
DIMENSION | 127*76*42mm (L*W*H) | |||||||||
PACKING | 0.21Kg; 54pcs/14.2Kg/1.35CUFT | |||||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Mounting holes M1 and M2 should be grounded for EMI purposes. |