RoHS 60W Triple Output Switching Power Supply
The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
Features:
Universal AC input / Full range
Protections: Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
Fixed switching frequency at 50 KHz
1 year warranty
60W Triple Output Power Supplies T-60 Series SpecificationMODEL | T-60A | T-60B | T-60C |
OUTPUT | OUTPUT NUMBER | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 |
DC VOLTAGE | 5V | 12V | -5V | 5V | 24V | -12V | 5V | 15V | -15V |
RATED CURRENT | 5A | 2.5A | 0.5A | 5A | 2.5A | 0.5A | 5A | 2A | 0.5A |
CURRENT RANGE | 0.5 ~ 7A | 0.2 ~ 3.5A | 0 ~ 1A | 0.5 ~ 7A | 0.2 ~ 3.5A | 0 ~ 1A | 0.5 ~ 7A | 0.2 ~ 3A | 0 ~ 1A |
RATED POWER | 57.5W | 61W | 62.5W |
RIPPLE & NOISE (max.) Note.2 | 100 mVp-p | 100 mVp-p | 100 mVp-p | 100 mVp-p | 100 mVp-p | 100 mVp-p | 100 mVp-p | 100 mVp-p | 100 mVp-p |
VOLTAGE ADJ. RANGE | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±6.0% | ±6.0% | ±2.0% | ±6.0% | ±6.0% | ±2.0% | ±6.0% | ±6.0% |
LINE REGULATION | ±0.5% | ±1.0% | ±0.5% | ±0.5% | ±1.0% | ±0.5% | ±0.5% | ±1.0% | ±0.5% |
LOAD REGULATION | ±1.0% | ±4.0% | ±1.0% | ±1.0% | ±4.0% | ±1.0% | ±1.0% | ±4.0% | ±1.0% |
SETUP, RISE, HOLD TIME | 300ms, 50ms, 80ms/230VAC800ms, 50ms,10ms/115VAC at full load |
INPUT | VOLTAGE RANGE | 85 ~ 264VAC120 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz |
EFFICIENCY (Typ.) | 72% | 72% | 72% |
AC CURRENT | 2A/115VAC1A/230VAC |
INRUSH CURRENT (max.) | COLD START 20A/115VAC40A/230VAC |
LEAKAGE CURRENT | <3.5mA / 240VAC |
PROTECTION | OVERLOAD | 105 ~ 150% rated output power. |
Protection type: Hiccup mode, recovers automatically after fault condition is removed. |
OVER VOLTAGE | CH1: 5.75 ~ 6.75V |
Protection type: Hiccup mode, recovers automatically after fault condition is removed. |
ENVIRONMENT | WORKING TEMP. | -10 ~ +60ºC |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY | -20 ~ +85ºC, 10 ~ 95% RH |
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
SAFETY & EMC (Note 4) | SAFETY STANDARDS | Design refer to UL1012, UL60950, TUV EN60950 |
WITHSTAND VOLTAGE | I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B |
HARMONIC CURRENT | Compliance to EN61000-3-2,-3 |
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A |
OTHERS | MTBF | 281.1K hrs min. MIL-HDBK-217F (25ºC) |
DIMENSION | 159*97*38mm (L*W*H) |
PACKING | 0.50Kg; 30pcs/16.5Kg/0.0250CMB |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºCof ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
60W Triple Output Power Supplies T-60 Series Mechanical Specification:
60W Triple Output Power Supplies T-60 Series Certificate for LVD:
60W Triple Output Power Supplies T-60 Series Certificate for EMC:
RoHS 60W Triple Output Switching Power Supply