50W CE approved Triple output switching power supply
Protection type: Fold back current limiting, recovers automatically after fault condition is removed.
WORKING TEMP.:-10 ~ +60ºC
AC CURRENT:1.6A/115VAC0.8A/230VAC
Features:
AC input range selectable by switch
Protections: Short circuit/Over load
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 24 KHz I/P-O/P: Rated
Low cost
High reliability
1 year warranty
50W Triple Output Switching Power Supply T-50 Series SpecificationMODEL | T-50A | T-50B | T-50C | T-50D |
OUTPUT | OUTPUT NUMBER | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 |
DC VOLTAGE | 5V | 12V | -5V | 5V | 24V | -12V | 5V | 15V | -15V | 5V | 12V | 24V |
RATED CURRENT | 7A | 1A | 1A | 5A | 1A | 1A | 4A | 1A | 1A | 3A | 1A | 1A |
CURRENT RANGE | 0.6 ~ 7A | 0.2 ~ 1A | 0.2 ~ 1A | 0.6 ~ 5A | 0.2 ~ 1A | 0.2 ~ 1A | 0.6 ~ 4A | 0.2 ~ 1A | 0.2 ~ 1A | 0.6 ~ 4A | 0.2 ~ 1.2A | 0.2 ~ 1.2A |
RATED POWER | 52W | 49W | 50W | 51W |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 50mVp-p | 120mVp-p | 120mVp-p |
VOLTAGE ADJ. RANGE | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±5.0% | ±5.0% | ±2.0% | ±5.0% | ±5.0% | ±2.0% | ±5.0% | ±5.0% | ±2.0% | ±6.0% | ±6.0% |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±1.0% | ±1.0% |
LOAD REGULATION | ±1.0% | ±4.0% | ±4.0% | ±1.0% | ±4.0% | ±4.0% | ±1.0% | ±4.0% | ±4.0% | ±1.0% | ±5.0% | ±5.0% |
SETUP, RISE, HOLD TIME | 200ms, 100ms, 16ms at full load |
INPUT | VOLTAGE RANGE | 85 ~ 132VAC/170 ~ 264VAC selected by switch240 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz |
EFFICIENCY (Typ.) | 66% | 69% | 71% | 72% |
AC CURRENT | 1.6A/115VAC0.8A/230VAC |
INRUSH CURRENT (max.) | COLD START 20A/115VAC40A/230VAC |
LEAKAGE CURRENT | <0.5mA / 240VAC |
PROTECTION | OVERLOAD | 105 ~ 150% rated output power. |
Protection type: Fold back current limiting, recovers automatically after fault condition is removed. |
ENVIRONMENT | WORKING TEMP. | -10 ~ +60ºC |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY | -20 ~ +85ºC, 10 ~ 95% RH |
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
SAFETY & EMC | SAFETY STANDARDS | Design refer to UL1012 |
WITHSTAND VOLTAGE | I/P-O/P: 1.5KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
OTHERS | MTBF | 470.2K hrs min. MIL-HDBK-217F (25ºC) |
DIMENSION | 159*97*38mm (L*W*H) |
PACKING | 0.49Kg/pc, 30pcs/16.2Kgs/0.0250CMBT |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. |
50W Triple Output Switching Power Supply T-50 Series Mechanical Specification:
50W Triple Output Switching Power Supply T-50 Series Certificate for LVD:
50W Triple Output Switching Power Supply T-50 Series Certificate for EMC:
50W CE approved Triple output switching power supply