40W AC Triple Output Switching Power Supply
Reasonable price and good Stability
OUTPUT:can be different kinds
CE approved
Features:
Universal AC input / Full range
Protections: Short circuit/Over load/Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 40 KHz
1 year warranty
40W Triple Output Power Supply T-40 Series SpecificationMODEL | T-40A | T-40B | T-40C |
OUTPUT | OUTPUT NUMBER | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 |
DC VOLTAGE | 5V | 12V | -5V | 5V | 12V | -12V | 5V | 15V | -15V |
RATED CURRENT | 3A | 2A | 0.5A | 3A | 2A | 0.5A | 3A | 1.5A | 0.5A |
CURRENT RANGE | 0.6 ~ 5A | 0.2 ~ 3A | 0.1 ~ 1A | 0.6 ~ 5A | 0.2 ~ 3A | 0.1 ~ 1A | 0.6 ~ 5A | 0.2 ~ 2A | 0.1 ~ 1A |
RATED POWER | 41.5W | 45W | 45W |
RIPPLE & NOISE (max.) Note.2 | 100 mVp-p | 120 mVp-p | 100 mVp-p | 100 mVp-p | 120 mVp-p | 120 mVp-p | 100 mVp-p | 120 mVp-p | 120 mVp-p |
VOLTAGE ADJ. RANGE | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±6.0% | ±8.0% | ±2.0% | ±6.0% | ±8.0% | ±2.0% | ±6.0% | ±6.0% |
LINE REGULATION | ±0.5% | ±1.0% | ±1.0% | ±0.5% | ±1.0% | ±1.0% | ±0.5% | ±1.0% | ±1.0% |
LOAD REGULATION | ±0.5% | ±4.0% | ±6.0% | ±0.5% | ±4.0% | ±6.0% | ±0.5% | ±4.0% | ±4.0% |
SETUP, RISE, HOLD TIME | 800ms, 50ms, 70ms/230VAC1600ms, 50ms,16ms/115VAC at fullload |
INPUT | VOLTAGE RANGE | 85 ~ 264VAC120 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz |
EFFICIENCY (Typ.) | 72%/115VAC | 72%/115VAC | 72%/115VAC |
AC CURRENT | 1.2A/115VAC0.7A/230VAC |
INRUSH CURRENT (max.) | COLD START 20A/115VAC40A/230VAC |
LEAKAGE CURRENT | <3.5mA / 240VAC |
PROTECTION | OVERLOAD | 105 ~ 150% rated output power. |
Protection type: Hiccup mode, recovers automatically after fault condition is removed. |
OVER VOLTAGE | CH1: 5.75 ~ 6.75V |
Protection type: Hiccup mode, recovers automatically after fault condition is removed. |
ENVIRONMENT | WORKING TEMP. | -10 ~ +60ºC |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY | -20 ~ +85ºC, 10 ~ 95% RH |
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
SAFETY & EMC (Note 4) | SAFETY STANDARDS | Design refer to CSA 60950-1, (UL60950-1, IEC60950-1, TUV EN60950-1) |
WITHSTAND VOLTAGE | I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B |
HARMONIC CURRENT | Compliance to EN61000-3-2,-3 |
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A |
OTHERS | MTBF | 305.6K hrs min. MIL-HDBK-217F (25ºC) |
DIMENSION | 129*98*38mm (L*W*H) |
PACKING | 0.39Kg; 45pcs/19.6Kg/0.0326CMB |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºCof ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
40W Triple Output Power Supply T-40 Series Mechanical Specification:
40W Triple Output Power Supply T-40 Series Certificate for LVD:
40W Triple Output Power Supply T-40 Series Certificate for EMC:
40W AC Triple Output Switching Power Supply