Min. Order: | 200 Piece/Pieces |
---|---|
Trade Term: | FOB |
Payment Terms: | L/C, T/T, WU |
Supply Ability: | 30000 Pieces / Month |
Place of Origin: | Zhejiang |
Location: | Wenzhou, Zhejiang, China (Mainland) |
---|---|
Business Type: | Manufacturer, Trading Company |
Model No.: | NES-150-5 |
---|---|
Means of Transport: | Ocean, Air |
Input Voltage: | 220V |
Output Type: | Single |
Output Power: | 101 - 200W |
Brand Name: | INTMW |
Output Voltage: | 5V |
Output Frequency: | N/A |
Output Current: | 26A |
Dimension: | 199*98*38mm (L*W*H) |
Certificate: | CE, RoHS |
Color: | Silver |
Shell Material: | Aluminum & Iron |
Safety Compliance: | EMC & LVD |
Weight: | 0.7Kg |
Input Frequency: | 50 / 60Hz |
Production Capacity: | 30000 Pieces / Month |
Packing: | 0.7Kg; 30pcs/22Kg/1.24CUFT |
Delivery Date: | 7 ~ 15 Days |
MODEL | NES-150-5 | |
OUTPUT | DC VOLTAGE | 5V |
RATED CURRENT | 26A | |
CURRENT RANGE | 0 ~ 26A | |
RATED POWER | 130W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | |
VOLTAGE ADJ. RANGE | 4.75 ~ 5.5V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | |
LINE REGULATION Note.4 | ±0.5% | |
LOAD REGULATION Note.5 | ±1.0% | |
SETUP, RISE, HOLD TIME | 800ms, 20ms, 24ms/230VAC1200ms, 30ms, 20ms/115VACat full load | |
INPUT | VOLTAGE RANGE | 90 ~ 132VAC / 180 ~ 264VAC selected by switch254 ~ 373VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 78% | |
AC CURRENT(Typ.) | 3A/115VAC2A/230VAC | |
INRUSH CURRENT (Typ.) | COLD START 40A/230VAC | |
LEAKAGE CURRENT | <2mA / 240VAC | |
PROTECTION | OVERLOAD | 110 ~ 150% rated output power |
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 5.75 ~ 6.75V | |
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||
ENVIRONMENT | WORKING TEMP. | -20 ~ +60ºC |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40 ~ +85ºC, 10 ~ 95% RH | |
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) | |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |
SAFETY & EMC(Note.6) | SAFETY STANDARDS | Design refer to UL60950-1, TUV EN60950-1 |
WITHSTAND VOLTAGE | I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | |
EMI CONDUCTION & RADIATION | Compliance to EN55022(CISPR22) Class B | |
HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | |
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A | |
OTHERS | MTBF | 433.3Khrs min. MIL-HDBK-217F (25ºC) |
DIMENSION | 199*98*38mm (L*W*H) | |
PACKING | 0.7Kg; 30pcs/22Kg/1.24CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12"twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. |