40W Switched Mode Power Supply S-40-15
Features:
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 75 KHz
1 year warranty
40W Switched Mode Power Supply S-40-15 SpecificationMODEL | S-40-15 |
OUTPUT | DC VOLTAGE | 15V |
RATED CURRENT | 2.8A |
CURRENT RANGE | 0 ~ 2.8A |
RATED POWER | 42W |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p |
VOLTAGE ADJ. RANGE | 13.5 ~ 16.5V |
VOLTAGE TOLERANCE Note.3 | ±1.0% |
LINE REGULATION | ±0.5% |
LOAD REGULATION | ±0.5% |
SETUP, RISE TIME | 300ms, 50ms/230VAC 800ms, 50ms/115VAC at full load |
HOLD TIME(Typ.) | 70ms/230VAC 15ms/115VAC at full load |
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz |
EFFICIENCY (Typ.) | 76%/115VAC |
AC CURRENT | 1.2A/115VAC 0.6A/230VAC |
INRUSH CURRENT (max.) | COLD START 25A/115VAC 50A/230VAC |
LEAKAGE CURRENT | <1mA / 240VAC |
PROTECTION | OVERLOAD | 105 ~ 150% rated output power |
Protection type: Hiccup mode, recovers automatically after fault condition is removed. |
OVER VOLTAGE | 17.25 ~ 20.25V |
Protection type: Hiccup mode, recovers automatically after fault condition is removed. |
ENVIRONMENT | WORKING TEMP. | -10 ~ +60ºC |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY | -20 ~ +85ºC, 10 ~ 95% RH |
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
SAFETY & EMC (Note 4) | SAFETY STANDARDS | Design refer to UL1012, UL1950, TUV EN60950 |
WITHSTAND VOLTAGE | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B |
HARMONIC CURRENT | Compliance to EN61000-3-2,-3 |
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5; ENV50204, EN55024, Light industry level, criteria A |
OTHERS | MTBF | 314.1K hrs min. MIL-HDBK-217F (25ºC) |
DIMENSION | 129*98*38mm (L*W*H) |
PACKING | 0.412Kg; 45pcs/20.43Kg/0.0326CMB |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
40W Switched Mode Power Supply S-40-15 Mechanical Specification:
40W Switched Mode Power Supply S-40-15 Certificate for LVD:
S-40-15 Certificate for EMC: