RT INTELLIGENT ON-LINE UPS:
· True intelligent UPS with the MCU control.
· True on-line UPS. pure sine wave output.
· Using the pwer unit IGBT to make the UPS more efficiency and reliable.
· Output three phase 100% unbalanced load, operate continuously.
· Unique output short circuit protection, jump-free main switch.
electronic power
· It is safe and reliable with the isolation transformer.
· Whole protection against load, auto limitcurrent, it is conformed to the start requiremen of different load.
· DC cold start ability can provide convenient and flexible progamme for the users.
· Long standby time, it also can be connected with the generator and constitute the long standby time.
· Obtained remote control, remote control, remote survey port(standard equipment) and provide remote supervisory indicator.
· Offer ATS hot standby redundancy capability, it can constitute the 220VDC input inverter for the special use of power station.
electronic power
SPECIFICATION |
MODEL | RT10 | RT15 | RT20 | RT30 | RT40 | RT60 | RT80 | RT100 | RT125 | RT150 | Capacity | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 125KVA | 150KVA | Input | | Voltage | Three phase and four wire | Range | ±20% | Frequency | 50Hz±50% | Output | | Voltage | Three phase and four wire 380V 380V±1%(Static state); 380V±1%(Load 0~100% change) | Frequency | (The unit oscilation) Simultaneously with line input(main power status) | Overload capacity | 120% Operate continuosly:125-150% 30S | Crest ratio | 3:1 | THD | Harmonic distortion of the phase voltage main wave<3%(100% Linear load) | Wave form | Pure sine wave | 100% Unbalanced load | Operate continuosly | Power factor | 0.8-1 Lagging | Efficiency | >90% | Transfer Time | Commercial power bypass Inverter 0ms; Inverter Commercial power<1ms | Short circuit | Output shut, Not change to bypass | Battery | | Battery Voltage | 192VCD 220VDC (Specialuse use of power station) | 192VDC/384VDC 220VDC (Specialuse use of power station) | Floating-charge Voltage | 220VDC | 220VDC/440VDC | End voltage | 170VDC | 170VDC/340VDC | Recharing Current | 6-50 ADC | Communication Between Human And Machine | LCD | Big screen dot-maxtrix display operating staus, voltage, current, parameter, model, set etc. | LED | Procedure display double route input, rectifier, inverter, battery, bypass output, static state switch, fault | Port | Communication Port | True RS-232 port | Remote control and remote survey | Remote turn on and turn off; Working status | A.T.S Port | 24VDC | Enviroment | | Audible Noise | <55dB | <60dB | Working Temperature | 0~40oC | Relative Humidity | 90% | Protecting Standard | Ip21 | Color | Light grey | Physical | | WxDxH(mm) | 410x850x1150 | 800x750x1620 | 800x750x1850 | 700x19000x1800 | Net Weight(KG) | 220 | 235 | 255 | 450 | 500 | 540 | 800 | 1100 | 1700 | 1800 |
|