Min. Order: | 100 Meter |
---|---|
Trade Term: | FOB,CFR,CIF,EXW |
Payment Terms: | Paypal, L/C, D/P, D/A, T/T, WU, Money Gram |
Supply Ability: | 350000 Kilometers per Month |
Place of Origin: | Henan |
Location: | Zhengzhou, Henan, China (Mainland) |
---|---|
Business Type: | Manufacturer, Trading Company |
Model No.: | New zealand LV Power Cable |
---|---|
Means of Transport: | Ocean, Air, Land |
Shielding: | Others |
Insulation Material: | XLPE |
Jacket: | PVC |
Conductor Material: | Aluminum |
Brand Name: | Huadong Cable Group |
Type:: | LV HV MV |
Conductor Material:: | Aluminum or Copper |
Insulation:: | XLPE/PVC |
Jacket:: | PVC or PE |
Application:: | Construction |
Standard:: | GB12706,GB12666,IEC60502,IEC60331 |
Certification:: | ISO9001, ISO14001, OHSAS18001,CCC |
Port:: | Qingdao/Tianjin/Shanghai/Ningbo/Guangzhou |
Production Capacity: | 350000 Kilometers per Month |
Packing: | Packaging in Standard wooden /steel drum,others as your request. |
Delivery Date: | 10-20 working days after payment |
Cu conductor XLPE insulated PVC sheated steel wire armored power cable not only have excellent electric, mechanical properties, but also have powerful resistance against chemical corrosion, heataging and environmental stress. Their structures are simple. The permissible maximum operating temperature is 90'C. It is convenient for using, and they can be laid with no restriction of different elevation.
| 1st class | 0.6/1 | 1.8/3 | 3.6/6 | 6/10 | 8.7/15 | 12/20 | 18/30 | 21/35 | |||
2nd class | 1/1 | 3/3 | 6/6 | 8.7/10 | 12/15 | 18/20 | - | 26/35 | ||||
1 Core | 1.5-800 | 25-800 | 25-1200 | 25-1200 | 35-1200 | 50-1200 | 50-1200 | 50-1200 | ||||
2 Core | 1.5-185 | 25-185 | ||||||||||
3 Core | 1.5-400 | 25-400 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 | ||||
4 Core | 2.5-400 | 25-400 | ||||||||||
5 Core | 2.5-400 | 25-400 |
Type | Name | Main Application | |
Cu Core | Al Core | ||
YJV YJY | YJLV YJLV | XLPE insulated,PVC or PE Sheathed Power Cable | For laying indoor,tunnel,channel and undergroud,Unable to bear external mechanical force,but bear the traction force during laid |
YJV22 YJV22 | YJLV22 YJV22 | XLPE Insulated,Steel Tape Armoured,PVC or PE Sheathed Power Cable | For laying indoor,tunnel,channel and undergroud Able to bear external mechanical force,but unable to bear large pulling force |
YJV32 YJV32 | YJLV32 YJLV32 | XLPE Insulated,Fine Steel Wire Armoured,PVC or PE Sheathed Power Cable | For laying in shaft with large difference of level.Able to bear external machanical force and maderate pulling force |
YJV42 YJV42 | YJLV42 YJLV42 | XLPE Insulated,Thick Steel Wire Armoured,PVC or PE Sheathed Power Cable | Able to bear positive pressure and pulling force |
Note:"ZR-"Include ABC three kinds of flame retardent cables,which are spectively indicated in "ZRA-" or "ZRB-" "ZRC-".For example:"ZRB-YJV","ZRA-YJV22".
Main Technical Quota
1.DC resistance:conductor resistance of finished cable at 20'C per kilometer is not more than the following values.
Nominal Section Area(mm 2 ) | 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 |
Copper Core | 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283 0.0221 |
Aluminum Core | 18.1 12.1 7.41 4.61 3.08 1.91 1.20 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.778 0.0605 0.0469 0.0367 |
2.Voltage Test and Partial Discharge Test
| 0.6/1 | 1.8/3 | 3.6/6 | 6/6 6/10 | 8.7/10 8.7/15 | 12/20 | 18/20 18/30 | 21/35 | 26/35 | |||
Voltage | Test Voltage | 3.5 | 6.5 | 12.5 | 21 | 30.5 | 42 | 63 | 73.5 | 91 | ||
Test Time | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | |||
Partial Discharge Test | Test Voltage | - | - | 6.2 | 10.4 | 15.1 | 20.8 | 31.1 | 36.3 | 45 | ||
Discharge Capacity | - | - | 10 | 10 | 10 | 10 | 10 | 10 | 10 |