1000va~20kva online ups
1. Features
1.Optional high efficency mode
2. Optional free run mode(CVCF)
3.Optional remote monitoring panel
4.LCD/LED display with customized setting intormation.
5.Extended backup time
6.Power management software
7.N+X parallel redundancy
8.DSP control
2. online ups specification
Model | | 1K | 1KS | 2K | 2KS | 3K | 3KS | 6K | 6KS | 10K | 10KS | 3/1 10KS | 3/1 15KS | 3/1 20KS |
CAPACITY | VA/W | 1000VA/700W | 2000VA/1400W | 3000VA/2100W | 6000VA/4200W | 10000VA/7000W | 15KVA/10.5KW | 20KVA/14KW |
Voltage Range | 160~300VAC@full load(110~300VAC@half load) | 277~520VAC@full load |
Frequency Range | 46~54Hz / 56~60Hz |
Phase | Single Phase with groud | Three Phase In/Single Phase Out |
Current THD | < 5% |
Power Factor | ≥0.99 |
Generator Input | Support |
OUTPUT | Voltage | 208VAC/220VAC/230VAC/240VAC |
Voltage Regulation | ±1% |
Frequency (Syn.Range) | 46~54Hz / 56~60Hz |
Frequency (Battery Mode) | 50~60Hz/±1% |
Current Crest Ratio | 3:1 |
Harmonic Distortion | ≤2% THD (linear load) / ≤5% THD (No-linear load) |
Output Waveform | Pure sine wave |
Outlet | IEC×4 | IEC×6 | IEC×4+Terminal | Hard wiring terminal block |
Overload capacity | Line Mode:10min@100%~130% |
Battery Mode:30s@100%~130% |
EFFICIENCY | AC Mode | 87% | 90% |
Battery Type | 83% | 90% |
ECC Mode | 97% |
BATTERY | Battery Type | 12v/7AH | | 12v/7AH | | 12v/7AH | | 12v/7AH | | 12v/7AH | | Depending On The Capacity of External Batteries |
Numbers of Batteries | 3 | 8 | 8 | 20 | 20 |
Backup Time(Full Load) | >5mins | >5mins | >5mins | >5mins | >5mins |
Recharge Time(to 90%) | 5 Hours | 5 Hours | 5 Hours | 5 Hours | 5 Hours |
Charging Current(Max) | 1.0A | 4.0/8.0A | 1.0A | 4.0/8.0A | 1.0A | 4.0/8.0A | 1.0A | 4.0/8.0A | 1.0A | 4.0/8.0A | | | |
Rated Charging Voltage | 41.0v DC | 81.9V DC | 109.2V DC | 273V DC |
Temperature Compensation | Yes |
TRANSFER TIME | AC TO DC | Zero |
Inverter to Bypass | <4ms;Zero with Optional STS | Zero |
OPTIONAL FEATURES | Economic Mode(ECO Mode) | support |
Free Run Mode(CVCF) | support |
PDU(Power Distribution Unit) | support |
Remote Panel | Wired Type,Up to 100M Length |
Parallel Redundancy | Up to 4 Units maxium(Option) |
| | |
DIMENSION | Tower Case(D*W*H)mm | 400*145*220 | | 460*192*348 | 460*192*348 | 570*260*717 |
WEIGHT | Tower Case(kgs) | 14 | 7 | 34 | 13.5 | 35 | 14 | 90 | 35 | 93 | 38 | 38.5 | 65 | 65 |
ENVIRONMENT | Operating Environment | 0~40°C |
Relative Humidity | 20~90%(Non-Considensing) |
Noise Level | <55db@1 Meter | < 60db@1 Meter |
INTERFACE | Smart RS-232 | Software supports Windows Family.Sun Solaris,IBM Aix,Compaq True64,SGIIRIX ,FreeBSD.HP-UX,and MAC |
USB (Option) | Windows Family& MAC |
Internal Slot(Option) | SNMP/AS400 Relay Card/Rs485 |
EPO(Option) | Support Emergency Shutdown |