Min. Order: | 1000 Piece/Pieces |
---|---|
Payment Terms: | T/T |
Supply Ability: | 10000/day |
Place of Origin: | Guangdong |
Location: | Dongguan, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer, Service |
Main Products: | Controller EDR28 Audio Output High Frequency Transformer, Lighting Transformer And Flyback Transformer, LED Driver Dimmable Transformer, High Frequency Transformer For Power Supply, Switching Power Supply Transformers |
Model No.: | EE35 |
---|---|
Means of Transport: | Ocean, Air, Land |
Brand Name: | HangTung |
Usage: | Power |
Phase: | Single |
Bobbin: | EE35 Vertical 2+2PIN or as require |
core: | PC44 or as require |
Coil Number: | Applications |
Certificate: | UL/SGS/ROHS |
Model No: | EE19/EE22/EE25/EE28/EE30/EE35 |
Production Capacity: | 10000/day |
Packing: | carton |
Delivery Date: | 15-30days |
KEY FEATURES:
EE35 for PC power transformers distribution transformer testing equipments
EE35 high-frequency transformer Features
1. window area is large,
2.It is easy to wind
3.reasonable price
4. high reliability
ELECTRICAL SPECIFICATIONS:
Model | EE35 |
Bobbin type | Vertical |
L (MAX) | 30 |
W (MAX) | 28 |
H (MAX) | 36 |
side 1 (PIN spacing) | 2 |
20 | |
side 2 PIN (PIN spacing) | 2 |
20 | |
row spacing | 22 |
PIN diameter | 0.8 |
Output power | 30 to 600 W |
Operation frequency | 20kHz-500KHz |
Operation temperature | -40℃ to +125℃ |
Storage temperature | -25℃ to +85℃ |
Storage humidity | 30 to 95% |
Remark |
Remark: The above are the common types , other types are not listed temporarily. Our company can produce all kinds of EE high-frequency transformer with different specification according to clients. Welcome to inquiry. |
Applicaton | EE35 high frequency transformer is often used for DC-DC converter, drive transformer, PC power transformers etc.
|
Price | EE35 high frequency transformer's Price range is generally between 4-10 yuan, the price depends on the degree of complexity of the process, the customer requirements for raw materials, as well as if all meet to safety certification and so on. |
Packing:
1. Protect product with polyfoam and multi layer paper board.
2. Special protect carton for exporting product.
3. Per customer requirement.
Tradeterms:
1. Supply ability:50000 units/month
2. MOQ:1 units
3. OEM/ODM:Supply
4. Port:Guangzhou
5. Available trade terms:FOB, CIF ,CFR, EXW.
6. Delivery time:about 15 days after receiving you deposit
7. Payment:L/C,T/T, Paypal, etc.
Our Service & Advantages:
1.Reply your inquiry in 24 working hours.
2. Professional staff answer all your questions in fluent English.
3. More than 11 years experience to manufacture for the controller and power
supply in China.
4.Engaged in researching and developing for the high technology and with some patent.
5.A team of designers and engineers are capable to create new items according to customer request.
6.5 years warranty!
7.Welcome OEM and ODM.
8.Cooperate with some famous company.
9. Quality is our culture.
10. Provide good customer service is our obligation.
Application:Transformers are also used extensively in electronic products to step-down the supply voltage to a level suitable for the low voltage circuits they contain. The transformer also electrically isolates the end user from contact with the supply voltage.
Transformer introduction:A transformer is a static electrical device that transfers energy byinductive coupling between its winding circuits. A varying current in theprimary winding creates a varying magnetic flux in the transformer's coreand thus a varying magnetic flux through the secondary winding. This varying magnetic flux induces a varying electromotive force (emf) orvoltage in the secondary winding. Transformers can be used to vary the relative voltage of circuits or isolate them, or both.
Transformers range in size from thumbnail-sized used in microphones to units weighing hundreds of tons interconnecting the power grid. A wide range of transformer designs are used in electronic and electric power applications. Transformers are essential for the transmission,distribution, and utilization of electrical energy.
Transformer universal emf equation
If the flux in the core is purelysinusoidal, the relationship for either winding between its rms voltage Erms of the winding, and the supply frequency f, number of turns N, core cross-sectional area a in m2 and peak magnetic flux densityBpeak in Wb/m2 or T (tesla) is given by the universal emf equation:[15]
If the flux does not contain evenharmonics the following equation can be used for half-cycle average voltageEavg of any waveshape:
The time-derivative term in Faraday's Law shows that the flux in the core is the integral with respect to time of the applied voltage.[25] Hypothetically an ideal transformer would work with direct-current excitation, with the core flux increasing linearly with time.[26] In practice, the flux rises to the point where magnetic saturation of the core occurs, causing a large increase in the magnetizing current and overheating the transformer. All practical transformers must therefore operate with alternating (or pulsed direct) current.[26]
The emf of a transformer at a given flux density increases with frequency.[15] By operating at higher frequencies, transformers can be physically more compact because a given core is able to transfer more power without reaching saturation and fewer turns are needed to achieve the same impedance. However, properties such as core loss and conductor skin effect also increase with frequency. Aircraft and military equipment employ 400 Hz power supplies which reduce core and winding weight.[27] Conversely, frequencies used for some railway electrification systems were much lower (e.g. 16.7 Hz and 25 Hz) than normal utility frequencies (50 – 60 Hz) for historical reasons concerned mainly with the limitations of early electric traction motors. As such, the transformers used to step-down the high over-head line voltages (e.g. 15 kV) were much heavier for the same power rating than those designed only for the higher frequencies.
Power transformer over-excitation condition caused by decreased frequency; flux (green), iron core's magnetic characteristics (red) and magnetizing current (blue).
Operation of a transformer at its designed voltage but at a higher frequency than intended will lead to reduced magnetizing current. At a lower frequency, the magnetizing current will increase. Operation of a transformer at other than its design frequency may require assessment of voltages, losses, and cooling to establish if safe operation is practical. For example, transformers may need to be equipped with 'volts per hertz' over-excitation relays to protect the transformer from overvoltage at higher than rated frequency.
One example of state-of-the-art design is traction transformers used for electric multiple unit and high speed train service operating across the,country border and using different electrical standards, such transformers' being restricted to be positioned below the passenger compartment. The power supply to, and converter equipment being supply by, such traction transformers have to accommodate different input frequencies and voltage (ranging from as high as 50 Hz down to 16.7 Hz and rated up to 25 kV) while being suitable for multiple AC asynchronous motor and DC converters & motors with varying harmonics mitigation filtering requirements.
Large power transformers are vulnerable to insulation failure due to transient voltages with high-frequency components, such as caused in switching or by lightning.
Packaging & Delivery
Packaging Detail: standard export neutral packing or as customer's requirement
Delivery Detail: 15 days after receiving deposit
Factory of our company:
We will feel appreciated if you can provide the parameters of the product or the photo of the item.
We can supply kinds of transformers, The products are widely used in a large variety of industries, computer, switch power, home appliances,LED,Plasma color television, instrumentation, green lighting, instrument and apparatus, the automobile electronics, and military industry. The product can be made of various specs,wecan supply the ferrite core to match the trasformers.
All products of the size,electrical performance can be designed according to customer requirements in R&D.
If you have a project or looking for electronic parts and components please contact with us!
Don't hesitate to contact us if any interested in our products.
Hang Tung Co. LTD Tel: 86-769-86638188
skype:yjy090919