1.Details
Model | KDG7000SE |
Frequency. | 50 HZ | 60 HZ |
Max. AC output. | 5.5KVA | 6.0KVA |
Rated AC output. | 5.0KVA | 5.5KVA |
Phase. | single phase.or three phase |
Insulation. | F |
Rated AC voltage. | 115/230.220.230.240/110.120.110/220.120/240 |
Engine . | |
Model. | FD186FA |
Engine Type. | Air Cooled,4 Stroke,Single Cylinder |
Max power output. | 10.0HP |
Displacement. | 420cc |
Compressing ratio. | 2.0: 1 |
Engine speed. | 3000rpm | 3600rpm |
Starting system. | Electric(copper wire) |
Fuel tank capacity. | 16L |
Noise level(at 7m)/. | 70db(A) |
N.W./G.W. | 145/155kg |
Packing Dimension. | 955x575x860mm |
2.Our advantage
10 years experience.Stable diesel engine. Optional ATS (Automatic Transfer Switch),
movable trailers, soundproof canopy, base fuel tank, PC remote control .
Compare to other diesel generator unit, the fuel cost. of our generator are lower.
The quality guarantee:1 year. Our generator get CE ISO EPA approved.
3.Certifications.Get CE ISO EPA...APPROVED,WE can offer OEM
4.Using:
Use for house hold. locomotives, construction equipment, telecommunications, underground, automobiles, hospital ,boat and countless industrial applications. Usually, Three-phase power generators are primarily used for industrial purposes. For home use, single-phase power generators are sufficient
5.Caution:
a.To prevent the fire,Never ad fuel to the fuel tank while the engine is running.
Wipe off the overflowed fuel oil with a clean cloth, keep explosives and other flammable products
away from the generating set.
b.To prevent from inhaling the exhaust.Exhaust gas contains poisonous carbon monoxide,
which is harmful to the health, never use the generating set at the confined places or poor ventilated locations,
if it is necessary to run the generating set indoors, be sure to provide the adequate ventilation.
c.Be care not to be scalded.The muffler and the engine body are very hot while the engine is running
or just after running,do not touch these parts to prvent from being scaled