APPLICATION
1.R60M Earth leakage circuit breaker(elcb) is suiable to the circuit of AC50/60Hz,rated voltage 230V for 2pole and 400V for 4pole,and rated current 63A.When people come across the eletric shock or the leakage current of the electrical network exceeds the fixed value,this product can cut off the fault current in a second so to protect person and the equipments.It also can be used in the infrequent starting of the circuit and motors.This circuit breaker is suitable to industry,commerce,high-rise building,household and other kinds of places.This product conforms to IEC1008-1.It has the following characteristics:
2.Do not need any auxiliary power,having overcame the shortage of the electronic product(the Anti-jamming is not satisfying,easily be affected by the voltage of the ecectrical network and the lose of the protective for the cutting of the neutral axis),and then enlarge the protective range of the residual current;Rated conditional current can reach 4.5KA;Reliability will still be the same in the polluted environments;The enclosure and the parts all are adopted the with imported plastic materials which is high fire-resistant,heat-resistant and shookproof.Size is modulated with easily installed;Dynamic test installation,which makes the button more nimble and reliable.
Main specification and technical parameters
1.Main specifications:
According to rated current In: 16A,25A,40A,63A; Classing by residual acting current:0.03A, 0.1A, 0.3A;
According to the number of poles: a, two-pole electromagnetic leakage circuit breaker b, four-pole electromagnetic leakage circuit breaker
2.technical parameters:
Rated making and breaking capacity Im: 500A (In=25A,40A), 630A (In=63A); rated residualmarking and breaking capacity 500A (In=25A,40A), 630A(In=63A); m: 500A (In=25A,40A), 630A(In=63A); rated conditional short circuit current Inc:6KA; rated conditional residual short-circuit current c:4.5KA; rated residual non-acting no: 0.51n;
Breaking time of residual current acting
In A | In A | Breaking time(In) when residual current is equal to the following values |
In 2In 5In 500A |
16,25,40.63 | 0.03,0.1,0.3 | 0.1 0.08 0.04 0.04 max breaking time |
Mechanically electrical endurance: Electromagnetic leakage circuit breaker should bear the cycles specified below
Electromagnetic leakage circuit breaker should bear the current impact with 200A peak value and surge overvoltage with 2.5 /2, and without causing wrong acting.
In(A) | operating | operating frequency(cycles/hour) |
load cycles non-load operating cycles |
25 | 2000 2000 | 240 |
40,63 | 2000 2000 | 120 |
Insulation and shock proof voltage performance: A, when connected together, each pole can bear the impulse voltage of 6000V peak value with neutral pole; B, each pole connecting with neutral pole can bear the impulse voltage of 3000V peak value between metal brackets.
Electrical features | Standard | | IEC/EN 60947-2 |
rated current in | A | 63,80,100,125 |
Poles | | 1P,2P,3P,4P |
Rated voltage Ue | V | 240/415 |
Insulation voltage Ui | V | 500 |
rated frequency | Hz | 50/60 |
Rated breaking capacity | A | 6000 |
Rated mpulse withstand voltage(1.2/50)Uimp | V | 6000 |
Dielectric test voltage at and ind.Freq, for 1 min | Kv | 2.5 |
pollution degree | | 3 |
Thermo-magnetic release characteristic | | 8-12In |
Mechenical features
| Electrical life | | 1500(In=63A,80A,100A) 1000(In=125A) |
Mechanical life | | 8500(In=63A,80A,100A) 7000(In=125A) |
Contact position indicator | | Yes |
Protection degree | | IP20 |
Reference temperature for setting of thermal element | | 30 |
Ambient temperature (with daily average ≤ 35 | | -5- +40 |
Storage temperation | | -25….+70 |
Terminal connection type | | Cable/Pin-type busbar |
Terminal size top/ bottom for busbar | mm2 | 50 |
AMG | 18-1/0 |
Tightening torque | N*m | 35 |
In-Ibs | 31 |
Mounting | | On Din rail FN 60715(35MM) by means of fast clip device |
Connection | | From top and bottom |
Combination with accessories | Auxiliary contact | | YES |
Shunt release | | YES |
Under voltage release | | YES |
Alarm contact | | YES |