user login

Power Supply China of 6-20KVA UPS Power with Output PF 0.9

420.0~1100.0 USD
Min. Order: 10 Piece/Pieces
Trade Term: FOB
Payment Terms: L/C, T/T, WU
Supply Ability: 200units/day
Place of Origin: Guangdong

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: Online DSP UPS, Uninterrupted Power Supply UPS, Inverters, America UPS, LINE- INVERACTIVE UPS

Product Detail

Model No.: PCP6-20Kva
Means of Transport: Ocean, Air, Land
Application: Security / Monitoring / Alarm
Phase: Single Phase
Type: On-line
Protection: Short Circuit
Brand Name: HRD/OEM
Weight: 28-72KG
Output Voltage: 220v
color: black
histroy record: 100pcs
output PF: 0.9
certifications: CE,ISO,TUV
EPO Function: standard
ECO function: standard
parallel: yes
SNMP: Optional
system: DSP control
power supply capacity: 6-20kva
Production Capacity: 200units/day
Packing: carton packing as export standard
Delivery Date: 20days after payment
Show

Product Description

Power Supply China of 6-20KVA UPS Power with Output PF 0.9

Features

1.DSP control ,with excellent performance and comprehensive protections for load and UPS                       

2. Output power factor 0.9,offering more stronger load capability

3.Intelligent fan speed control ,with 4 levels varying according to load and temperature

4.Wide input range ,support kinds of generator

5.Dual input AC source supportable

6. EPO(emergency power off)              

7.Event log up to 100 events, recording UPS running time and critical memories

8. High efficiency (ECO mode)option          

9.Intelligent N+X parallel redundancy, up to 6units

10.AC and cold start function

11. Human friendly large LCD, with plenty operation information

12. Conformal coating PCB for more critical operation environment

13. 3:1phase into single phase easy convertible (10-20Kva)

14. Frequency Convertor mode:input 50Hz,output 60Hz or reverse   

15. Most advanced 3 electrical level inverter designfor 15-20kva

16. Extremely low failure rate and easy repair(MTBF>80000h,MTBR<0.5h)

17.Intelligent  10A charger,prolong battery lifespan by above 20%:interval three-stage charging process( constant current.constant voltage, float charging) with inverse battery connection protection(option)

 

 

 

18. Multiple communication ports ,SNMP card, AS400 card(optional)

 

 Technical Specification

Model

PCP06S

PCP06L

PCP10S

PCP10L

PCP3110

PCP3115

PCP3120

Capacity(Kva/kW)

6KVA/5.4kW

10KVA/9kW

15KVA/13.5KW

20KVA/18kW

Input

Phase

1/1PHASE, 1wire+N+G

3/1APHASE, 3Wires+N+G

Input  PF

≥0.99

≥0.95

Input

voltage

Low

 transfer

L-N:176 VAC ± 3% @ 100% load;130 VAC ± 3% @ 50% load

Low back

L-N:188 VAC ± 3% @ 100% load,142   VAC ± 3% @ 50% load

High transfer

L-N:286 VAC ± 3%

High back

L-N:270 VAC ± 3%

Input frequency

40-70hz

Battery

Rating/type

12V/7Ah

depend on external

battery

12V/9Ah

depend on external

Battery

depend on   external battery capacity

quantity

20

20

Back up time

6mins

depend on external battery 

4mins

depend on external

Battery

DC voltage

240Vdc

Charge voltage

275Vdc

Recharging current

1A

4A

1A

4A/10A(option)

Output

Output  P.F

0.9

Output voltage

220/230/240Vac +/-1%(static)

Frequency

46~54Hz or 56~64Hz (Line mode)
  50/60Hz ± 0.1Hz ( Battery mode)

Crest factor

3:1(max)

Wave distortion

Less   than 2%(linear load), Less than 4% Non-linear load

Over load

105%<load<125%   for 1 mins ,125%<load<150% for30sec

Efficiency

92%(Line   mode)

98%(ECO   mode)

Transfer time

0ms   (AC-Battery);

0   ms(bypass-inverter)

Indicator

LCD Panel

UPS   status, Load level, Load watt,Load VA,Battery level, Input/Output voltage,   output current,Bus voltage, Temp, and warning and fault code and events

Alarm

Battery Mode

Sounding   every 4 seconds( can mute)

Low Battery

Sounding   every second

Overload

Sounding   every second

Fault

Continuously   sounding

Management

Smart RS-232/USB

Supports   Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC

Optional

SNMP/AS400/USB

Environment

Operation Humidity

0-90   % RH (non-condensing) @ 0- 40°C

Noise Level

Less   than 55dBA @ 1 Meter

Less   than 58dBA @ 1 Meter

Physical

Net Weight (KG)

62

22

76

29

36

45

45

Gross Weight(KG)

74

35

88

41

48

58

58

Unit Dimension

(D*W*H)mm

582*260*642

600*300*740

Packing   (D*W*H)mm

680*360*810

720*420*920

Note:6-10kva 120Vac models are available ;

All specifications subject to change without further notice; customized specifications are acceptable


PACKING & SHIPPING

 

Packing:

1-20KVA ONLINE HF UPS: CARTON PACKING WITH PALLET

6-600KVA ONLINE LF UPS and 10-120KVA ONLINE HF UPS: WOODEN PACKING WITH PALLET

 

Shipping: 3-4 WEEKS AFTER PREPAYMENT ; BY SEA/EXPRESS/AIR

 

 About us

 

 warranty

 

1-20KVA UPS : 18 months from shipment date

3/3 phase UPS : 2 years from shipment date

 

If any part fails within warranty and needs repairing or replacing, please send part or board back to us (customer pay the freight fee), Or you provide the exact details information as per our requirement, and we offer you free spare parts and send to you(customer pay the freight fee)

 

our service

 

1. Professional technical and business service before and after selling.

2. Professional free engineer training course in our factory or abroad.

3. Customer market protection policy.

4. Short delivery time and good quality and good price

5. fast and effective online technical and business support.

 

Our Mission and Vision :


Mission: Produce high quality UPS product and power solution to worldwide partners for middle and high end market;

Vision : To be a world-class company in UPS industry.

 

FAQ

 

1 what is uninterrupted power supply

An uninterruptible power supply, also uninterruptible power source, UPS, is an electrical apparatus that provides emergency power to a load when the input power source, typically mains power, fails. A UPS differs from an auxiliary or emergency power system or standby generator in that it will provide near-instantaneous protection from input power interruptions, by supplying energy stored in batteries, super capacitors, or flywheels. The on-battery runtime of most uninterruptible power sources is relatively short (only a few minutes) but sufficient to start a standby power source or properly shut down the protected equipment.

A UPS is typically used to protect hardware such as computers, data centers, telecommunication equipment or other electrical equipment where an unexpected power disruption could cause injuries, fatalities, serious business disruption or data loss. UPS units range in size from units designed to protect a single computer without a video monitor (around 200 volt-ampere rating) to large units powering entire data centers or buildings.

 

2 what is the difference between high frequency UPS and low frequency UPS?

 

Item

High frequency UPS

Low frequency UPS

Input PF

0.99

0.7

Efficiency  

85-90%

75-85%

Power   density

Higher

Lower

Power   device capacity

Less

More

Weight

Light

Heavy

Dimension  

Compact

Bigger

Price

Lower

Higher

Overload ability

Normal

Better

Anti   input sugar capacity

Normal

Better

Output   anti-crush , short circuit capacity

Normal

Better

N-G voltage

Bad

Better

Output   component

More

Less

Damage   extent of device when it's fail

Higher

Lower

Stability  

Normal

Better

Compatibility with   generator

Bad

Better

 

3 how to choose between standard model UPS and long time model UPS?

 

standard model UPS

long time model UPS

standard model UPS power means within batteries inside   UPS, the backup time would be only few minutes at full load

long time model UPS power means with external   batteries, the backup time would be different according to the battery   capacity

If the backup time at full load is   longer, long time model would be your choice , if the backup time at full   load is shorter, standard model UPS would be enough

 

4 how to contact me to get more details of HRD UPS power ?

 

Post Buying Request