user login

260KW Volvo series diesel generator set

10000.0~100000.0 USD
Min. Order: 1 Set/Sets
Trade Term: FOB
Payment Terms: T/T, WU
Supply Ability: 500sets/month
Place of Origin: Hebei

Company Profile

Location: China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: CDV [S/L]-260
Means of Transport: Ocean
Output Type: AC Three Phase
Brand Name: Dafeng
Speed: 1500rpm/1800rpm
Frequency: 50hz/60hz
Rated Power: 260KW/325KVA
Rated Voltage: 400V/200V
Rated Current: 468A
Usage: mining,railways,factories,business,hospitals
Production Capacity: 500sets/month
Packing: plastic wrapping
Delivery Date: 2-3 weeks
Show

Product Description

Engine data
manufacturer/model
VOLVO TAD941GE,4-cycle
Air Intake System
Turbo Air to air intercooler
Fuel System
Directly Injection Fuel System, Bosch Pump
Cylinder Arrangement
6 in line
Displacement
9.36L
Bore and Stroke
120*138(mm)
Compression Ratio
17.4
Rated RPM
1500rpm
Max. Standby Power at Rated RPM
308KW/419HP (with fan)
Governor Type
EMS2
Generator data
manufacturer
number of phase
Stanford/Leroy somer
3
Connecting Type
3 Phase and 4 Wires, "Y" type connecting
Number of Bearing
1
Power Factor
0.8
Protection Grade                   
IP23
Altitude
≤1000m
Exciter Type
Brushless, self-exciting
Insulation Class, Temperature Rise
H/H
Telephone Influence Factor (TIF)
<50
THF
<2%
Voltage Regulation, Steady State
≤±1%
Generator Capacity
350KVA
Generator Efficiencies
93.5%
Air Cooling Flow
0.8m3/s
Generating set data
Voltage Regulation
≥±5%
Voltage Regulation, Stead State
≤±1%
Sudden Voltage Warp (100% Sudden Reduce)
≤+20%
Sudden Voltage Warp (Sudden Increase)
≤-15%
Voltage Stable Time (100% Sudden Reduce)
≤4S
Voltage Stable Time (Sudden Increase)
≤4S
Frequency Regulation, Stead State
≤5%
Frequency Waving
≤0.5%
Sudden Frequency Warp (100% Sudden Reduce)
≤+10%
Sudden Frequency Warp (Sudden Increase)
≤-7%
Frequency Recovery Time (100% Sudden Reduce)
≤3S
Frequency Recovery Time (Sudden Increase)
≤3S
Noise Level
114dB
Operation
After diesel generator installed, you can put into power, before each start, at least the following items should be checked
1.whether unit surface and around has debris
2.keep the into and exhaust channel of the engine room is smooth
3.the cooling liquid tank is normal
4.the air filter indicator directs normal
5.lubricating oil level is within normal range
6.the fuel valve is open, the supply of fuel to engine is normal
7.battery cables are connected correctly
8.power load device is ready
,when the generator directly with the load, breaking the air switch before start.
Post Buying Request