30KW Three phase Deutz Diesel generator set

10000.0~100000.0 USD
Min. Order: 1 Set/Sets
Trade Term: FOB
Payment Terms: T/T, WU
Supply Ability: 500sets/month
Place of Origin: Hebei

Company Profile

Location: China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: CDD[S/L]-30
Means of Transport: Ocean
Output Type: AC Three Phase
Brand Name: Dafeng
Speed: 1500rpm/1800rpm
Frequency: 50hz/60hz
Rated Power: 30KW/38KVA
Rated Voltage: 400V/200V
Rated Current: 54A
Usage: mining,railways,factories,business,hospitals
Production Capacity: 500sets/month
Packing: plastic wrapping
Delivery Date: 2-3 weeks
Show

Product Description

Generating set model
CDD[S/L]-30
Prime
Standby
Gen-set power (KW)
30
33
Gen-set power (KVA)
38
41
Engine power (KW)
46
Engine model  
TD226B-3D
Engine manufacturer
Sino-Germany joint venture weichai-deutz co.,ltd
Engine configuration
3-cylinder in line, 4-stroke, spontaneously inspiration, direct spray fuel system
Engine cooling mode
The Radiator suitable for 40°CTemperature, Strap drive the cooling fan with protection cover
Speed control system
Mechanical speed controller, electricity - magnet valve control switch
Start mode
24V Direct Current Start, Including alternator & battery
Engine filter system
Dry air filter type, Fuel filters, Lube filter
Engine total displacement      (L)
3.12
Compress ratio
16.0/1
Bore*stroke          (mm)
105×120
100%load fuel consumption (L/h)
9.6
10.6
Specific fuel consumption          (g/kwh)
≤208
Lubricating oil consumption      (g/kwh)
≤1.36
Exhaust air flow           (m3/min)
60
Air consumption           (m3 /min)
2.8
Exhaust gas flow      (m3/min)
6.3
Exhaust gas temperature           (°C)
455
Oil capacity          (L)
7.25
Coolant capacity      (L)
15.5
Short circuit protection
MCCB Air switch
Rated voltage/frequency/power factors
400V/230V,50Hz,0.8 lag, 3-phase & 4-line
Stable frequency change rate
≤5%
Free load voltage adjusting range
≥95%—105%
Stable voltage regulator
≤±1%
Insulation class/protection grade
Hclass/IP23
Telephone influence factor       
TIF<50/ THF<2%
Accessory attached
A suit of start battery& connective wire; Exhaust smoke siphon, Ripple absorber, Flange, Muffler; absorber on base
Water tank ventilation area        (mm)
520*540
operation
After diesel generator installed, you can put into power, before each start, at least the following items should be checked
1.whether unit surface and around has debris
2.keep the into and exhaust channel of the engine room is smooth
3.the cooling liquid tank is normal
4.the air filter indicator directs normal
5.lubricating oil level is within normal range
6.the fuel valve is open, the supply of fuel to engine is normal
7.battery cables are connected correctly
8.power load device is ready
,when the generator directly with the load, breaking the air switch before start.
Post Buying Request