1.General
PZ96L-E3 power analyzer specializes in measuring the data of all kinds of AC networksIt may be used for local display, or it is connected with the control equipment in measuring and controlling system.
They comply EN 61326:2006 and EN 61010-1:2001. RoHS Directive 2002/95/EC.
They are a kind of programmable analyzer. With the 4 key on the front, we can set their parameters according to the network which we measure. They have many option functions. They can be equipped RS-485 communication Modbus-RTU; or they can output analog signal. With logic input or logic output, we can realize controlling other equipment remotely
They are a kind of analyzer with excellent cost performance, since they regroup the functions of traditional electric transmitter and digital meters. Therefore they are widely being used in kinds of control system, SCADA system and power management system.
2.Technical Measure
- Measurement: VL1, VL2, VL3,VL12, VL23, VL31,AL1, AL2, AL3, ∑AL, F,
∑P, P1,P2,P3, ∑Q, Q1,Q2,Q3,∑S, S1,S2,S3,∑PF, PF1,PF2,PF3,
MD kW,+kWh, +kvarh, -kWh, -kvarh
- Network: 1P2W, 3P3W, 3P4W
- Frequency: 45 ~ 65Hz
- Voltage: AC 3x120/220V, 3x230/400V, 3x400V (programmable);
overload: 480V (continuous); 800V during 30s; Consumption: < 0.2VA
- Current: AC 1A, 5A
Overload: 6A (continuous); 50A during 30s; Consumption: < 0.2VA
- Thermal drift: <200ppm
- Transformation ratio: CT and PT ratio can be programmable
- Precision: 0.5 (F: 0.05Hz; kVar: 1)
- Power supply: AC/DC 85 ~ 270V; Consumption < 4VA
- Test voltage: 2kVAC/min (voltage input / power; between current inputs); 1.5kVAC/min (outputs / power)
Insulation: input / housing and output / housing >100M
- Work T: -10C ~ +45C;Storage T: -20C ~ +70C
- Relative humidity: 5% ~ 95% (no condensation)
- Altitude: < 2500m
3. Options
- Communication (/C) : RS485 (Modbus-RTU);
1 start bit, 8 data bit, 1 stop bit, no parity,
speed (1200/2400/4800/9600/19200)
- Alarm output(/J): 1 passive relay (1A/30VDC, 1A/250VAC):
alarms of over voltage, low voltage and over current;
The hysteresis and the delay can be set
- Analog output(/M): DC4 ~ 20mA, DC0~20mA (load < 600Ω),
DC0 ~ 5V,DC1 ~ 5V (load > 1kΩ)
- Logic options(/K): 2DI/2DO;
DI: dry contact Input, supplied inside, optoisolator;
DO: NO-NC contact; 1A/30VDC,5A/250VAC ( to control other equipments)
4. Order examplee
Before your order, please inform us the range of current inputs and voltage inputs and options you need.
For example:
Need the 3 phase 96 model ammeter with RS485 communication, 2DI/2DO and LCD display, the range of current is 0-5A
The product type is PZ96L-E3/KC
5. Free Software
Use our free software to realize reading or setting our power analyzers on computer. (Please download free software on our website)
Other size: 72x72mm, 80x80mm,120x120mm, 144*144mm