user login

ZVF11 Series Mining Frequency Inverter

Company Profile

Location: Nanjing, Jiangsu, China (Mainland)
Business Type: Manufacturer
Main Products: Power Inverter, Solar Water Pump Solar Pump, UPS, Voltage Regulators, Solar Power System

Product Description

Feature
1. Adopt DSP microprocessor of TI company in America and IPM intellegent module.
2. Space voltage vector SAPWM control, few harmonic output, low noise.
3. Effect is very good of stop of DC braking capacity from 0%-100%
4. Four kinds time of acceleration/decelaration which can setting arbitrarily of time 0.1 second to 999.9 seconds.
5. Six multi-functional terminals which can setting arbitrarity of 24 kinds of purpose
6. PLC running which can setting of 16' stage running frequency and time.
7. Built-in PID and funciton of speed setting on pulse coder.
8. RS485 communication control adopt the popular MODBUS communication protector.
9. Appearance size with subminiature +keypad design with simple.
Specification:
Phase no.: Single-phase
Input voltage: AC110V or 200V or 220V or 240V
Output voltage: AC110V & 220V
With fuse protector or with over current protector.
Application:
All the Electronic Equipments.
Remarks:
Custom-made specifications are acceptable.

Input voltage class220V
ZVF11-M/S…0004S200075S20015S20022S2
Applicable motor power(KW)0.40.751.52.2
OutputOutput current2.34.57.510
Maximum output voltage(V)Three-phase 0~input voltage
Range of output frequency(Hz)0.0~400.00Hz
InputRange of input voltage160~240V
Range of input power frequency50/60Hz+/-55Hz
Control characteristicsControl modeSAPWM space vector control
Frequency resolutionDigital setting:0.01Hz; Analog setting: Maximum frequency: 0.1%
Torque characteristicsAdjustable from 0% to 20%
Overload capacity150% of the rated output current per minute
Acceleration/Deceleration timeAdjustable from 0.1 to 999.9
Linear/Quadratic
Running characteristicsFrequency setting signalPanel controlSet by the key or the potentiometer on the panel
External signalTerminal 0~10V, 4~20Ma, 0~10KHz, UP/DOWN, 485 COM etc.
Operation setting signalPanel
Control
Set by key RUN or STOP
Extent signalExternal FWD, REV and JOG operation, PLC operation and com operation
Multi-function input signalMulti phase spped, counter, program run, VI/CI shifting and etc.
Multi-function output signalFailure, running, counter arrival, frequency arrival program running
Analog output signalRunning frequency, output voltage, current, motor rotation
Other functionsAVR, overvoltage and current stall prevention, no reversal and etc.
Protecting functionsOvervoltage, overcurrent, under-voltage, overload, overheat, short circuit protection and etc.
Cooling modeForced air cooling
AmbientPoints of useAttitude<1000m, indoor places without corrosive gas, liquid and etc.
External EnvironmentTemperature:-10~+45?; humidity<90%RH without condensing
Vibration<0.5G
 
Post Buying Request