SR618C6 Solar Controllers Solar Water Heater Controllers Solar Smart Controllers

20.0~200.0 USD
Min. Order: 1 Set/Sets
Trade Term: FOB
Payment Terms: L/C, D/P, D/A, T/T, WU
Supply Ability: 50000pcs/year
Place of Origin: Jiangsu

Company Profile

Location: China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: SR618C6
Means of Transport: Air
Application: Water Heater
Type: Pressurized
Pipe Material: Glass
Brand Name: Ultisolar
Production Capacity: 50000pcs/year
Packing: standar carton
Delivery Date: 3
Show

Product Description

 
ModelSR618C6
Suitable forSplit solar water heater
Working Principle
Technical Data1.Appearance  of  controller:  see  product  itself  (  dimension:  210mm  x145mm  x48mm)
2.Power  supply:AC230V  ±10%      
3.Power  consumption:< 3W
4.Accuracy of temperature measuring: ± 2oC
5.Range of collector temperature measuring: -10 ~200 oC
6.Range of tank temperature measuring: 0 -100 oC
7.Suitable power of pump: 4 pumps possible to be connected, power of each pump ≤ 600W.
8.Suitable power of auxiliary heating:power ≤1500W
9.Inputs: 6 sensors,
           2 piece Pt1000 sensor (≤500oC) for collector (silicon cable≤280oC),
           4 pieces NTC10K, B3950 sensor (≤ 135oC) for tank, (PVC cable ≤105oC),
10.Ambient temperature :-10oC - 50oC.
11.Water proof grade:IP40.
Voltage220V,110V is availabe against request, 24V is available for 50 sets above order.
Main Function
1.SYSTME(SYS1~SYS12)
2.DT  O  &  DT  F    Temperature  difference  controlling  the  Solar  circuit  pump
3.THET  Timing  heating
4.EM  Emergency  collector  temperature(emergency  switch-off  temperature  of  collector)
5.CMX  Maximum  limited  collector  temperature(collector  cooling  function)
6.CMN  low  temperature  protection  of  collector
7.CFR  frost  protection  of  collector
8.SMX  Maximum  temperature  of  tank
9.REC  Tank  re-cooling  function
10.MAX1  Maximum  turnoff  temperature  (for  solid  fuel  boiler,  return  heating,  heat  transferring    between  tanks)
11.MIN1  Minimum  turn-on  temperature  (for  solid  fuel  boiler,  return  heating,  heating  transferring  between  tanks)
12.DVWG  Anti-Legionella  function
13.CIRC  Temperature  controlled  hot  water  circulation  pump
14.nMIN  Solar  circulation  pump  speed  adjusting(RPM  speed  controlling)
15.OHQM  Thermal  energy  measuring
16.Priority  logic  of  tank
17.INTV  Pump  interval  fucntion
18.BYPR  High  temperature  by-pass  function(Tank  temperature  automatically  adjusting)
19.Holiday  fucntion
20.HND  Manual  mode
21.PASS  Password  setting
22.RSET  Recovery  to  factory  setting
23.Manual  Heating
24.Temperature  query  function
25.Memory  Protection
26.Anti-dry  heating  protection
27.Screen  protection
28.Trouble  protection
Post Buying Request