Reliability level or 50000 hours MTBF& 0.5% annual field failure rate@25℃
Input AC230V, has the load to work for 12 hours or closes down for 12 hours to be able to work for
8640 hours
AC Input voltage rating 100Vac to 240Vac
AC Input voltage range 90Vac to 254Vac
AC Input frequency range 47Hz to 63Hz
Max. In-rush current 30A for 100Vac at full load75A for 240Vac at full load
Input current 1.5AMax @ 90V/60Hz full load
Standby power 0.5W Max @ 254V/50Hz no load
OUTPUT REQUIREMENTS
Output voltage +12V
Output voltage tolerance +/-0.6V
Min load current
0 mA
Max load current 3000mA
Line regulation +/-1%
load regulation +/-5%
Ripple & Noise
120mVp-p (max)
Total output power 36W typical
Efficiency 80% min@100~240Vac50/60Hz with full load
Hold up time 10m sec.min.@ 100Vac/60Hz with full load
Turn on delay time 3sec.max.@ 100Vac/60Hz with full load
Switching frequency 65K Hz typical