ABC cable/overhead cable/aerial cable/can be made according to the BS, IEC, ASIN, DIN, JIS, CSA standards. 1KV, 10KV, etc.
ABC cable/overhead cable/aerial cable/can be made according to the BS, IEC, ASIN, DIN, JIS, CSA standards. 1KV, 10KV, etc.
Aerial Bundle Cable (ABC cable), 0.6/1KV, XLPE insulation, Aluminum Conductor
Product Description
1. Application of Service Drop Cable:
Service Drop Cable (ABC CABLE) is mainly used for electric power transmission, rebuilding of urban and forest regions. They can improve the safety and reliability of electrified wire netting.
2. Type of Service Drop Cable:
Service Drop Cable (ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruple Service Drop
The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.
3. Detailed Introduction of Service Drop Cable
3.1 Duplex Service Drop
Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. To be sued for service at voltage of 600 volts or less and at conductor temperature not to exceed 75 degree.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.

3.2 Triplex Service Drop
Applications
To supply power from the utility's lines to the consumer's service head. For service at 600 Volts or less (phase to phase) at a conductor temperature of 75 degree maximum for PE insulation or 90 degree maximum for XLPE insulation.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
 3.3 Quadruple Service Drop
Applications
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum, and insulated with PE or XLPE. Neutral messengers are concentrically stranded 6210 AAAC, AAC or ACSR