Min. Order: | 1 Piece/Pieces |
---|---|
Payment Terms: | L/C, D/P, D/A, T/T, WU |
Supply Ability: | 1000 |
Place of Origin: | Guangdong |
Location: | China (Mainland) |
---|---|
Business Type: | Manufacturer, Trading Company |
Model No.: | INGA-11001 |
---|---|
Means of Transport: | Ocean, Air, Land |
Brand Name: | OEM |
Measurement: | CO, CO2, CH4, H2, O2, CnHm,heating value |
Resolution: | CO, CO2, CH4, H2, O2, CnHm: 0.01% |
Precision: | CO, CO2, CH4, CnHm: ≤ ±1%FSH2, O2: ≤ ±2%FS |
Repeatability: | CO, CO2, CH4, H2, O2, CnHm: ≤1% |
Flow rate: | 0.7-1.2L/min |
Inlet pressure: | 2kPa-50kPa |
Sampling gas condition: | no dust, no water vapor,no tar |
Response time: | T90<10s(NDIR) |
Signal output: | RS-232 digital output |
Power supply: | Built-in rechargeable lithium battery |
Production Capacity: | 1000 |
Packing: | box packed |
Delivery Date: | within 3 weeks |
Manufacturer : NDIR Portable Infrared Syngas Analyzer INGA-11001
Description:
The instrument can be used for measurement of the concentration of CO ,CO2 ,CH4 ,H2 and O2 in sample gases simultaneously and also calculated heating value(caloric value ) automatically. powered by Li- ion battery. Based on the NDIR and Thermal Conductivity Detector.
Application:
Coal or biomass gasification, coal chemical process, heating treatment, steel making process such as blast furnace, Converter, Coking, Direct Iron Ore Smelting Reduction Process.
Features:
--1. Adopt international advanced NDIR and TCD gas analysis technology.
--2. Can measure the concentration of CO ,CO2 ,CH4 ,H2 ,O2 ,CnHm simultaneously.
--3. Automatically calculated heating value,the unit can be switch on/off between Kcal/m³ and Mj/m³.
--4. CnHm gas has no interference with CH4 measuring result.
--5. H2 reading is compensated for the interference effects of the CO ,CO2 ,CH4 measured.
--6. Built-in sampling pump.
--7. Storage function.
--8. RS-232 digital output interface.
Specification:
--Measurement: CO, CO2, CH4, H2, O2, CnHm,heating value
--Technology: CO, CO2, CH4, CnHm : NDIR
--H2: TCD O2: ECD
--Rang: CO: 0-75% CO2: 0-25% CH4: 0-40%
H2: 0-75% O2: 0-25% CnHm: 0-5%
(Measurement range can be customized by the requirement)
--Resolution: CO, CO2, CH4, H2, O2, CnHm: 0.01%
--Precision: CO, CO2, CH4, CnHm: ≤ ±1%FS
H2, O2: ≤ ±2%FS
--Repeatability: CO, CO2, CH4, H2, O2, CnHm: ≤1%
--Flow rate: 0.7-1.2L/min
--Inlet pressure: 2kPa-50kPa
--Sampling gas condition : no dust, no water vapor,no tar
--Response time: T90<10s(NDIR)
--Signal output: RS-232 digital output
--Power supply: Built-in rechargeable lithium battery