Min. Order: | 3 Piece/Pieces |
---|---|
Payment Terms: | L/C, T/T, WU |
Supply Ability: | 10000 pieces per month |
Place of Origin: | Zhejiang |
Location: | Ningbo, Zhejiang, China (Mainland) |
---|---|
Business Type: | Manufacturer, Distributor/Wholesaler |
Model No.: | PCC-12/630 |
---|---|
Means of Transport: | Ocean, Air, Land |
Application: | Industrial |
Type: | Medium Voltage |
Insulation Material: | Rubber |
Jacket: | Rubber |
Conductor Material: | Others |
Brand Name: | PURANA |
Rated Voltage: | 12kV |
Rated Current: | 630A |
Material: | Silicon Rubber |
Applicable cable: | Copper core and XLPE cable with cross-sectional area 25mm2 to 400mm2 |
Application: | For connecting of 10kV and 12kV transformer, switchgear and outdoor cable branch boxes |
Production Capacity: | 10000 pieces per month |
Packing: | In cartons |
Delivery Date: | 10 warking days after receiving downpayment |
Application:
1. Using the pushing tecnique to install the accessories in order to improve the sealing effect;
2. Applicable for 10kV 25-400mm2 single core and triple cores XLPE cable with cable core Cu or Al;
3. For extrusion type cable and other screened flexible cable;
4. For connecting of 10kV transformer, switchgear and outdoor cable distribution boxes.
Features:
1. Advanced after-injected insulation process to make sure higer eletric performance, more safe and reliable;
2. 3mm exterior smooth shielding layer, with earthing resistance less than 100Ω to make sure the reliable earthing;
3. To reaize cable outgoing diversification by connector combinations, and connecting lenth is less 100mm than traditional type connector to make a smaller cubicle too save space;
4. Taking the geometric structure of the stress control unit and the internal shielding layer configuration to ease the electric field concentration, and using the pushing tecnique to install the accessories to make sure the sealing effect.
Cable connector parameters:
Serial No. | Test Item | Unit | Parameter |
1 | Rated Voltage | kV | 12 |
2 | Rated Current | A | 630 |
3 | Power Frenquce Withstand Voltage | kV/5min | 39 |
4 | Partial Discharge | kV≤10pC | 15 |
5 | Load Cycling Test | kV 500h | 23 |
6 | Lighting Impulse Withstand Voltage | kV | 95 |
7 | Negative Polarity DC Voltage | kV/15min | 35 |
12kV/630A Cable Connector Specification:
Serial No. | Cross-sectional Area/ mm2 | Insulation Diameter | |
Min. | Max. | ||
1 | 25, 35 | 16.00 | 19.00 |
2 | 50, 70, 95, 120 | 18.00 | 24.50 |
3 | 150, 185, 240 | 24.00 | 30.50 |
4 | 300, 400 | 30.00 | 36.00 |
Product show: