user login

12kV Nylon Embedded Pole

Min. Order: 3 Piece/Pieces
Payment Terms: L/C, T/T, WU
Supply Ability: 1500PCS/MONTH
Place of Origin: Zhejiang

Company Profile

Location: Ningbo, Zhejiang, China (Mainland)
Business Type: Manufacturer, Distributor/Wholesaler

Product Detail

Model No.: PES12/630-25
Means of Transport: Ocean, Air, Land
Type: High Voltage
Poles Number: 3
Brand Name: PURANA
Rated Voltage: 12kV
Rated Current: 630A/1250A/1600A
Rated Breaking Current: 25KA/31.5kA
Material: Environment-friendly materials Nylon
Type: Insulator
Production Capacity: 1500PCS/MONTH
Packing: In wooden cases
Delivery Date: 20-30 days after receiving downpayment
Show

Product Description

Advantages:

The production of the VI housing is made of environment-friendly materials, so it can be recycled to reduce environmental pollution;  

High dielectric strength and mechanical strength;

The housing of embedded pole is made of nylon which is fire retardant stronger;

Optimum protection of the vacuum interrupter from moisture, dust and external damage;

Suitable for all conceivable climatic conditions and site altitudes;

Absolutely reliable with long service life;

Easy assembly on circuit-breakers;

Highest quality standard;

Maintenance-free;

Efficient increase in dielectric strength without use of greenhouse gases.


Main Technical Datas:


1Rated voltage12kV
2Rated Current630A/1250A/1600A
3Rated frequency50/60HZ
4Rated short-circuit breaking current25KA/31.5kA
5Breaking operations of rated short-circuit breaking current30 times
6Rated short-circuit making current63KA/80kA
7Rated peak withstand current63KA/80kA
8Rated short-time withstand current(4s)25KA/31.5kA
9Rated breaking current of single capacitor bank630A
10Rated breaking current of back-to-back capactior bank400A
11Short-time power-frequency withstand voltage (1min)48KV
12Lightning impulse withstand voltage (peak)85KV
13Circuit resistance at rated contact force≤20µΩ
14Mechanical endurance30000 times
15Contact closing force due to bellows and atmosphere 100±30N
16Counterforce at rated contact storke200±30N
17Contact limit erosion3mm
18Storage life20 years
19Partial discharge≤1PC
20Rated operating sequence0-0.3s-CO-180s-CO

Mechanical Datas of Vacuum Circuit Breaker:


1Rated contact stroke9±1mm
2Contact connect storke4±1mm
3Average opening speed1.1±0.2m/s
4Average closing speed0.7±0.2m/s
5Rate contact pressure3000±200N
6Contact bouncing duration at closing operation≤2ms
7Out of simultaneity of contact closing and opening ≤1ms
8Max. Overtravel≤2mm
The matching plastic contact arm sleeve:

Post Buying Request